Evidence map›Paper›PMID 35789872›Full record

ArticleHeliyon2022

Water vapor desorption from silica gel in a combined drying and double-condenser compression refrigeration system.

Engkos Achmad Kosasih, Ahmad Zikri, Muhammad Irfan Dzaky

Open access · goldAbstract read
In one paragraph

Article in Heliyon, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
1.5field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 16 citations in OpenAlex.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Engkos Achmad KosasihDepartment of Mechanical Engineering, Faculty of Engineering, Universitas Indonesia, Kampus UI Depok 16424, West Java, Indonesia.
Ahmad ZikriDepartment of Mechanical Engineering, Faculty of Engineering, Universitas Indonesia, Kampus UI Depok 16424, West Java, Indonesia.
Muhammad Irfan DzakyDepartment of Mechanical Engineering, Faculty of Engineering, Universitas Indonesia, Kampus UI Depok 16424, West Java, Indonesia.
University of Indonesia · ID

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The drying method requires an effort to store food for a longer time. Some drying processes experience technical and economic weaknesses, mainly related to low efficiency, high energy costs, and decreased product quality. Various drying models have been studied to determine the suitability of heat and mass transfer analysis at drying rates in an air dehumidification scheme using different materials, one of which is silica gel. In this case, the researchers examined the effects of humidity, temperature, and airflow rate on the constant drying rate and activation energy of water desorption in silica gel using a packed bed dryer that was modified with a refrigeration system. This modified system aims to reduce specific energy consumption (SEC). The results demonstrate that the constant rate of water desorption in silica gel and the increase in air humidity cause a decrease in the constant value of the water desorption rate in silica gel. However, increases in the temperature and airflow cause an increase in the value of the constant drying rate for water desorption in silica gel, as they cause capillary evaporation. Meanwhile, the activation energy of water desorption in silica gel increases with decreasing air flow rate and increasing inlet air humidity. The attractive force acting on the water molecules from the surface force field on the surrounding walls becomes stronger if the air flow rate decreases or the air humidity increases. From the results and analysis, it is shown that the activation energy of water desorption in silica gel with significant air humidity and low flow rate, of 0.013 kg/kg d.a. (450 lpm), is the highest at 35.16 kJ/mol, whereas in silica gel with air humidity of 0.007 kg/kg d.a. (750 lpm), it is the lowest at 22.92 kJ/mol. Meanwhile, the dryer air flow rate, higher heater temperature, and lower air humidity improve the performance of the bed dryer against its evaporation rate and decrease the Specific Energy Consumption (SEC) value. SEC is also greatly influenced by the use condenser 1, which provides heater power savings of up to 79.1%. Thus, the system is expected to be applied to commercial drying systems that can work at low drying temperatures to maintain drying products and obtain low energy consumption.

Indexed as

Activation energyAir dehumidificationDesorptionDesorption rate constantRefrigerationSilica gel

Identifiers

PMID35789872
PMCPMC9249840
OpenAlexW4283261586

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.