ArticleJournal of robotic surgery2023
Comparison of robot-assisted versus fluoroscopy-assisted minimally invasive transforaminal lumbar interbody fusion for degenerative lumbar spinal diseases: 2-year follow-up.
Article in Journal of robotic surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 23 papers, 9 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
23 citing papers in PubMed, 9 syntheses or guidelines pooled it, 31 citations in OpenAlex.
- Robot-assisted versus fluoroscopy-guided spinal fusion for lumbar spondylolisthesis: a GRADE-assessed meta-analysis on surgical parameters, clinical outcomes, and complications.Journal of robotic surgery · 2026Pooled it
- Spine-specific robots may offer superior screw placement accuracy in spinal surgery procedures. A systematic review and network and proportional meta-analysis.Journal of orthopaedic surgery and research · 2025Pooled it
- Efficacy and safety of robot-assisted pedicle screw placement in lumbar spondylolisthesis: a meta-analysis.Journal of robotic surgery · 2025Pooled it
- Meta-analysis of TiRobot-assisted lumbar interbody fusion for degenerative lumbar disease: a comprehensive evaluation of screw placement accuracy and clinical safety.Journal of robotic surgery · 2025Pooled it
- Accuracy and Safety Between Robot-Assisted and Conventional Freehand Fluoroscope-Assisted Placement of Pedicle Screws in Thoracolumbar Spine: Meta-Analysis.Medicina (Kaunas, Lithuania) · 2025Pooled it
- Comparison of robot-assisted versus fluoroscopy-guided transforaminal lumbar interbody fusion (TLIF) for lumbar degenerative diseases: a systematic review and meta-analysis of randomized controlled trails and cohort studies.Systematic reviews · 2024Pooled it
- Effectiveness and safety of robot-assisted minimally invasive transforaminal lumbar interbody fusion for degenerative lumbar spinal diseases: a systematic review and meta-analysis.Journal of robotic surgery · 2024Pooled it
- Efficacy and safety of robot-assisted versus fluoroscopy-assisted PKP or PVP for osteoporotic vertebral compression fractures: a systematic review and meta-analysis.Journal of robotic surgery · 2023Pooled it
- Comparison of short-term clinical outcomes between robot-assisted and freehand pedicle screw placement in spine surgery: a meta-analysis and systematic review.Journal of orthopaedic surgery and research · 2023Pooled it
- Robot-assisted surgery for degenerative lumbar spine diseases: a disease-specific bibliometric and knowledge-mapping analysis.Journal of robotic surgery · 2026Article
- Robot-assisted versus conventional posterior lumbar interbody fusion for lumbar spinal stenosis: a propensity score-matched cohort study on total and hidden blood loss.Journal of orthopaedic surgery and research · 2026Article
- Navigation-assisted vs robot -assisted unilateral biportal endoscopic lumbar interbody fusion for single-level lumbar degenerative disease: a retrospective comparative study.Wideochirurgia i inne techniki maloinwazyjne = Videosurgery and other miniinvasive techniques · 2026Article
- Robot-assisted pedicle screw placement in spinal surgery: an updated systematic umbrella review and meta-meta-analysis of comparisons against freehand and navigation-guided techniques.EFORT open reviews · 2026Article
- Robot-assisted spinal surgery: technological maturity, clinical evidence, and future directions.Frontiers in robotics and AI · 2026Review
- Superior facet joint violation after lumbar pedicle screw placement: a scoping review of prevalence, biomechanics, and implications for adjacent segment disease.Asian spine journal · 2025Article
- Accuracy of Robotic-Guided Pedicular Screw Insertion in Thoracolumbar Spinal Surgery.Journal of clinical medicine · 2025Article
- Robot-assistedWorld journal of orthopedics · 2025Article
- Robotic-assisted minimally invasive transforaminal lumbar interbody fusion: A meta-analysis of perioperative and postoperative outcomes.Qatar medical journal · 2025Review
- [Effectiveness of robot-assisted minimally invasive and open freehand transforaminal lumbar interbody fusion in treatment of single-level degenerative lumbar spondylolisthesis and the influence on adjacent segment degeneration].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2024Article
- Evaluating the Status and Promising Potential of Robotic Spinal Surgery Systems.Orthopaedic surgery · 2024Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 1 institution in 1 country.
Funding
Abstract
This study was performed to prospectively compare the clinical and radiographic outcomes between robot-assisted minimally invasive transforaminal lumbar interbody fusion (RA MIS-TLIF) and fluoroscopy-assisted minimally invasive transforaminal lumbar interbody fusion (FA MIS-TLIF) in patients with degenerative lumbar spinal diseases. One hundred and twenty-three patients with lumbar degenerative diseases (lumbar spinal stenosis with instability and spondylolisthesis [degenerative spondylolisthesis or isthmic spondylolisthesis]) who underwent MIS-TLIF in our hospital were included in this study. Sixty-one patients underwent RA MIS-TLIF (Group A) and 62 patients underwent FA MIS-TLIF (Group B). Group A was further divided into Subgroup AI (46 single-level procedures) and Subgroup AII (15 double-level procedures). Group B was further divided into Subgroup BI (45 single-level procedures) and Subgroup BII (17 double-level procedures). The clinical outcome parameters were the visual analog scale (VAS) score, Oswestry Disability Index (ODI) score, operative time, number of intraoperative fluoroscopies, blood loss, postoperative hospital stay, and postoperative complications. The radiographic change measures were the accuracy of screw placement, facet joint violation (FJV), fusion status, and change in disc height at the proximal adjacent segment at the 2-year follow-up. There were no significant differences in the VAS and ODI scores, blood loss, or postoperative hospital stay between Groups A and B (p > 0.05). The operative time was longer in Group A than B (p = 0.018). The operative time was longer in Subgroup AI than BI (p = 0.001). However, there was no significant difference between Subgroups AII and BII (p > 0.05). There was no significant difference in the number of intraoperative fluoroscopies for patients between Groups A and B (p > 0.05). Although the number of intraoperative fluoroscopies for patients was significantly higher in Subgroup AI than BI (p = 0.019), there was no significant difference between Subgroups AII and BII (p > 0.05). The number of intraoperative fluoroscopies for the surgeon was significantly lower in Group A than B (p < 0.001). For surgeons, the difference in the average number of intraoperative fluoroscopies between Subgroups AI and AII was 2.98, but that between Subgroups BI and BII was 10.73. In Group A, three guide pins exhibited drift and one patient developed a lateral wall violation by a pedicle screw. One pedicle screw perforated the anterior wall of the vertebral body and another caused an inner wall violation in Group B. The rate of a perfect screw position (grade A) was higher in Group A than B (p < 0.001). However, there was no significant difference in the proportion of clinically acceptable screws (grades A and B) between the two groups. The mean FJV grade was significantly higher in Group B than A (p < 0.001). During at 2-year postoperative follow-up, there was no significant difference in the fusion status between the two groups (p > 0.05); however, the decrease in disc height at the proximal adjacent segment was significantly less in Group A than B (p < 0.001). Robot-assisted percutaneous pedicle screw placement is a safer and more accurate alternative to conventional freehand fluoroscopy-assisted percutaneous pedicle screw insertion in MIS-TLIF.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.