Evidence map›Paper›PMID 35788202›Full record

ArticlePloS one2022

Effects of tonotopic matching and spatial cues on segregation of competing speech in simulations of bilateral cochlear implants.

Mathew Thomas, Shelby Willis, John J Galvin, Qian-Jie Fu

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.4field-weighted citation impact, top 45% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Mathew ThomasDepartment of Head and Neck Surgery, David Geffen School of Medicine, UCLA, Los Angeles, CA, United States of America.ORCID 0000-0003-3322-8768
Shelby WillisDepartment of Head and Neck Surgery, David Geffen School of Medicine, UCLA, Los Angeles, CA, United States of America.
John J GalvinHouse Institute Foundation, Los Angeles, California, United States of America.
Qian-Jie FuDepartment of Head and Neck Surgery, David Geffen School of Medicine, UCLA, Los Angeles, CA, United States of America.ORCID 0000-0003-3494-7633
University of California, Los Angeles · USHouse Clinic · US

Funding

Frequency mismatch and spectral integration in acoustic and electric hearingR01DC017738 · NIDCD · UNIVERSITY OF CALIFORNIA LOS ANGELES · PI FU, QIAN-JIE · 2019 to 2023
$2.3M
Integration of acoustic and electric hearing within or across earsR01DC016883 · NIDCD · UNIVERSITY OF CALIFORNIA LOS ANGELES · PI FU, QIAN-JIE · 2019 to 2023
$1.7M
NIDCD NIH HHS R01 DC016883NIDCD NIH HHS R01 DC017738
6 · The paper itself

Abstract

In the clinical fitting of cochlear implants (CIs), the lowest input acoustic frequency is typically much lower than the characteristic frequency associated with the most apical electrode position, due to the limited electrode insertion depth. For bilateral CI users, electrode positions may differ across ears. However, the same acoustic-to-electrode frequency allocation table (FAT) is typically assigned to both ears. As such, bilateral CI users may experience both intra-aural frequency mismatch within each ear and inter-aural mismatch across ears. This inter-aural mismatch may limit the ability of bilateral CI users to take advantage of spatial cues when attempting to segregate competing speech. Adjusting the FAT to tonotopically match the electrode position in each ear (i.e., increasing the low acoustic input frequency) is theorized to reduce this inter-aural mismatch. Unfortunately, this approach may also introduce the loss of acoustic information below the modified input acoustic frequency. The present study explored the trade-off between reduced inter-aural frequency mismatch and low-frequency information loss for segregation of competing speech. Normal-hearing participants were tested while listening to acoustic simulations of bilateral CIs. Speech reception thresholds (SRTs) were measured for target sentences produced by a male talker in the presence of two different male talkers. Masker speech was either co-located with or spatially separated from the target speech. The bilateral CI simulations were produced by 16-channel sinewave vocoders; the simulated insertion depth was fixed in one ear and varied in the other ear, resulting in an inter-aural mismatch of 0, 2, or 6 mm in terms of cochlear place. Two FAT conditions were compared: 1) clinical (200-8000 Hz in both ears), or 2) matched to the simulated insertion depth in each ear. Results showed that SRTs were significantly lower with the matched than with the clinical FAT, regardless of the insertion depth or spatial configuration of the masker speech. The largest improvement in SRTs with the matched FAT was observed when the inter-aural mismatch was largest (6 mm). These results suggest that minimizing inter-aural mismatch with tonotopically matched FATs may benefit bilateral CI users' ability to segregate competing speech despite substantial low-frequency information loss in ears with shallow insertion depths.

Indexed as

Cochlear ImplantationCochlear ImplantsSpeech PerceptionCuesHumansMaleSpeech

Identifiers

PMID35788202
PMCPMC9255761
OpenAlexW4284694641

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.