ArticleFrontiers in neuroscience2022
Reducing Behavioral Detection Thresholds per Electrode
Article in Frontiers in neuroscience, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
15 citing papers in PubMed, 10 citations in OpenAlex.
- Long-term safety and efficacy of intracortical microstimulation in humans.Science translational medicine · 2026Trial
- Learning induces activation-mechanism-dependent neural plasticity in an intracortical microstimulation task.Science advances · 2026Article
- Neural population dynamics of direct electrical stimulation of neocortex.Cell reports · 2026Article
- Neural mechanisms underlying intracortical microstimulation for sensory restoration.Nature biomedical engineering · 2026Review
- Intracortical Microstimulation in Brain-Computer Interfaces: Evoking Perception and Plasticity.Cyborg and bionic systems (Washington, D.C.) · 2026Review
- Linking spatially distributed neuronal activation overlap to the limits of perceptual discrimination in rodent primary somatosensory cortex.Frontiers in computational neuroscience · 2026Article
- Neural population dynamics of direct electrical stimulation of neocortex.bioRxiv : the preprint server for biology · 2025Article
- A bioelectric router for adaptive isochronous neurostimulation enables multipolar bioelectric stimulation from a single source.Scientific reports · 2025Article
- Investigating the spatial limits of somatotopic and depth-dependent sensory discrimination stimuli in rats via intracortical microstimulation.Frontiers in neuroscience · 2025Article
- Stability Assessment of Ultramicroelectrode Arrays in Neural Stimulation: an Electrochemical Impedance Spectroscopy Analysis.Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2024Article
- Flexible Polymer Electrodes for Stable Prosthetic Visual Perception in Mice.Advanced healthcare materials · 2024Article
- Amplitude- and frequency-dependent activation of layer II/III neurons by intracortical microstimulation.iScience · 2023Article
- Behavioral Paradigm for the Evaluation of Stimulation-Evoked Somatosensory Perception Thresholds in Rats.bioRxiv : the preprint server for biology · 2023Article
- Layer-dependent stability of intracortical recordings and neuronal cell loss.Frontiers in neuroscience · 2023Article
- Behavioral paradigm for the evaluation of stimulation-evoked somatosensory perception thresholds in rats.Frontiers in neuroscience · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
Abstract
Intracortical microstimulation (ICMS) has shown promise in restoring quality of life to patients suffering from paralysis, specifically when used in the primary somatosensory cortex (S1). However, these benefits can be hampered by long-term degradation of electrode performance due to the brain's foreign body response. Advances in microfabrication techniques have allowed for the development of neuroprostheses with subcellular electrodes, which are characterized by greater versatility and a less detrimental immune response during chronic use. These probes are hypothesized to enable more selective, higher-resolution stimulation of cortical tissue with long-term implants. However, microstimulation using physiologically relevant charges with these smaller-scale devices can damage electrode sites and reduce the efficacy of the overall device. Studies have shown promise in bypassing this limitation by spreading the stimulation charge between multiple channels in an implanted electrode array, but to our knowledge the usefulness of this strategy in laminar arrays with electrode sites spanning each layer of the cortex remains unexplored. To investigate the efficacy of simultaneous multi-channel ICMS in electrode arrays with stimulation sites spanning cortical depth, we implanted laminar electrode arrays in the primary somatosensory cortex of rats trained in a behavioral avoidance paradigm. By measuring detection thresholds, we were able to quantify improvements in ICMS performance using a simultaneous multi-channel stimulation paradigm. The charge required per site to elicit detection thresholds was halved when stimulating from two adjacent electrode sites, although the overall charge used by the implant was increased. This reduction in threshold charge was more pronounced when stimulating with more than two channels and lessened with greater distance between stimulating channels. Our findings suggest that these improvements are based on the synchronicity and polarity of each stimulus, leading us to conclude that these improvements in stimulation efficiency per electrode are due to charge summation as opposed to a summation of neural responses to stimulation. Additionally, the per-site charge reductions are seen regardless of the cortical depth of each utilized channel. This evocation of physiological detection thresholds with lower stimulation currents per electrode site has implications for the feasibility of stimulation regimes in future advanced neuroprosthetic devices, which could benefit from reducing the charge output per site.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.