Evidence map›Paper›PMID 35783364›Full record

ArticleFrontiers in neurorobotics2022

A Multi-User Transradial Functional-Test Socket for Validation of New Myoelectric Prosthetic Control Strategies.

Taylor C Hansen, Abigail R Citterman, Eric S Stone, Troy N Tully, Christopher M Baschuk, Christopher C Duncan, Jacob A George

Open access · goldAbstract read
In one paragraph

Article in Frontiers in neurorobotics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.5field-weighted citation impact, top 43% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Preliminary Investigation of Myoelectric Control of an Assistive Neck Exoskeleton by Individuals With Amyotrophic Lateral Sclerosis.IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society · 2026
    Article
  3. Article
  4. Quantifying the Cognitive Demand of Controlling a Prosthesis with a Secondary Detection Response Task.Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2025
    Article
  5. Article
  6. Validity and Impact of Methods for Collecting Training Data for Myoelectric Prosthetic Control Algorithms.IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Taylor C HansenDepartment of Biomedical Engineering, University of Utah, Salt Lake City, UT, United States.
Abigail R CittermanDepartment of Biomedical Engineering, University of Utah, Salt Lake City, UT, United States.
Eric S StoneDepartment of Biomedical Engineering, University of Utah, Salt Lake City, UT, United States.
Troy N TullyDepartment of Biomedical Engineering, University of Utah, Salt Lake City, UT, United States.
Christopher M BaschukHandspring, Salt Lake City, UT, United States.
Christopher C DuncanDepartment of Physical Medicine and Rehabilitation, University of Utah, Salt Lake City, UT, United States.
Jacob A GeorgeDepartment of Biomedical Engineering, University of Utah, Salt Lake City, UT, United States.
University of Utah · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The validation of myoelectric prosthetic control strategies for individuals experiencing upper-limb loss is hindered by the time and cost affiliated with traditional custom-fabricated sockets. Consequently, researchers often rely upon virtual reality or robotic arms to validate novel control strategies, which limits end-user involvement. Prosthetists fabricate diagnostic check sockets to assess and refine socket fit, but these clinical techniques are not readily available to researchers and are not intended to assess functionality for control strategies. Here we present a multi-user, low-cost, transradial, functional-test socket for short-term research use that can be custom-fit and donned rapidly, used in conjunction with various electromyography configurations, and adapted for use with various residual limbs and terminal devices. In this study, participants with upper-limb amputation completed functional tasks in physical and virtual environments both with and without the socket, and they reported on their perceived comfort level over time. The functional-test socket was fabricated prior to participants' arrival, iteratively fitted by the researchers within 10 mins, and donned in under 1 min (excluding electrode placement, which will vary for different use cases). It accommodated multiple individuals and terminal devices and had a total cost of materials under $10 USD. Across all participants, the socket did not significantly impede functional task performance or reduce the electromyography signal-to-noise ratio. The socket was rated as comfortable enough for at least 2 h of use, though it was expectedly perceived as less comfortable than a clinically-prescribed daily-use socket. The development of this multi-user, transradial, functional-test socket constitutes an important step toward increased end-user participation in advanced myoelectric prosthetic research. The socket design has been open-sourced and is available for other researchers.

Indexed as

fabrication techniquesmyoelectricprostheticssocket designtransradial

Identifiers

PMID35783364
PMCPMC9247306
OpenAlexW4283023014

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.