Evidence map›Paper›PMID 35782660›Full record

ArticleIndian journal of anaesthesia2022

Automated versus manual B-lines counting, left ventricular outflow tract velocity time integral and inferior vena cava collapsibility index in COVID-19 patients.

Srinath Damodaran, Anuja Vijay Kulkarni, Vikneswaran Gunaseelan, Vimal Raj, Muralidhar Kanchi

Open access · diamondAbstract read
In one paragraph

Article in Indian journal of anaesthesia, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
3.1field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 15 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
  7. Trends in research inIndian journal of anaesthesia · 2023
    Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 2 countries.

Srinath DamodaranDepartment of Anaesthesia and Intensive Care, Narayana Institute of Cardiac Sciences, Narayana Health City, Bengaluru, Karnataka, India.
Anuja Vijay KulkarniDepartment of Anaesthesia and Intensive Care, Narayana Institute of Cardiac Sciences, Narayana Health City, Bengaluru, Karnataka, India.
Vikneswaran GunaseelanDepartment of Clinical Research, Narayana Institute of Cardiac Sciences, Narayana Health City, Bengaluru, Karnataka, India.
Vimal RajDepartment of Radiology, Narayana Institute of Cardiac Sciences, Narayana Health City, Bengaluru, Karnataka, India.
Muralidhar KanchiDepartment of Anaesthesia and Intensive Care, Narayana Institute of Cardiac Sciences, Narayana Health City, Bengaluru, Karnataka, India.
Narayana Health · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background and Aims: The incorporation of artificial intelligence (AI) in point-of-care ultrasound (POCUS) has become a very useful tool to quickly assess cardiorespiratory function in coronavirus disease (COVID)-19 patients. The objective of this study was to test the agreement between manual and automated B-lines counting, left ventricular outflow tract velocity time integral (LVOT-VTI) and inferior vena cava collapsibility index (IVC-CI) in suspected or confirmed COVID-19 patients using AI integrated POCUS. In addition, we investigated the inter-observer, intra-observer variability and reliability of assessment of echocardiographic parameters using AI by a novice. Methods: Two experienced sonographers in POCUS and one novice learner independently and consecutively performed ultrasound assessment of B-lines counting, LVOT-VTI and IVC-CI in 83 suspected and confirmed COVID-19 cases which included both manual and AI methods. Results: Agreement between automated and manual assessment of LVOT-VTI, and IVC-CI were excellent [intraclass correlation coefficient (ICC) 0.98, Conclusion: AI-guided assessment of LVOT-VTI, IVC-CI and B-lines counting is reliable and consistent with manual assessment in COVID-19 patients. Novices can reliably estimate LVOT-VTI and IVC-CI using AI software in COVID-19 patients.

Indexed as

Artificial intelligenceB-linesCOVID-19point-of-care ultrasound

Identifiers

PMID35782660
PMCPMC9241188
OpenAlexW4283838069

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.