Evidence map›Paper›PMID 35782242›Full record

ArticleQuantitative imaging in medicine and surgery2022

Effect of contrast material injection protocol on first-pass myocardial perfusion assessed by dual-energy dual-layer computed tomography.

Sara Boccalini, Salim Si-Mohamed, Maxime Matzuzzi, Manon Tillier, David C Rotzinger, Didier Revel, Loic Boussel, Philippe Douek

Open access · diamondAbstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.9field-weighted citation impact, top 31% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 11 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 6 institutions in 2 countries.

Sara Boccalini *Department of Cardiovascular and Thoracic Radiology, Hospices Civils de Lyon, Lyon, France.
Salim Si-Mohamed *Department of Cardiovascular and Thoracic Radiology, Hospices Civils de Lyon, Lyon, France.
Maxime MatzuzziFaculty of Medicine Rockfeller, University Claude Bernard Lyon 1, Lyon, France.
Manon TillierFaculty of Medicine Rockfeller, University Claude Bernard Lyon 1, Lyon, France.
David C RotzingerDepartment of Radiology, University Hospital Center Vaudois, Lausanne, Switzerland.
Didier RevelDepartment of Cardiovascular and Thoracic Radiology, Hospices Civils de Lyon, Lyon, France.
Loic BousselDepartment of Cardiovascular and Thoracic Radiology, Hospices Civils de Lyon, Lyon, France.
Philippe DouekDepartment of Cardiovascular and Thoracic Radiology, Hospices Civils de Lyon, Lyon, France.
Inserm · FRUniversité Claude Bernard Lyon 1 · FRCentre de Recherche en Acquisition et Traitement de l'Image pour la Santé · FRCentre National de la Recherche Scientifique · FRHospices Civils de Lyon · FRUniversity Hospital of Lausanne · CH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Dual-energy dual-layer computed tomography (CT) scanners can provide useful tools, such as iodine maps and virtual monochromatic images (VMI), for the evaluation of myocardial perfusion defects. Data about the influence of acquisition protocols and normal values are still lacking. Methods: Clinically indicated coronary CT-angiographies performed between January-October 2018 in a single university hospital with dual-energy dual-layer CT (DE-DLCT) and different injection protocols were retrospectively evaluated. The two protocols were: 35 mL in patients <80 kg and 0.5 mL/kg in patients >80 kg at 2.5 mL/s (group A) or double contrast dose at 5 mL/s (group B). Patients with coronary stenosis >50% were excluded. Regions of interest were manually drawn on 16 myocardial segments and iodine concentration was measured in mg/mL. Signal-to-noise, contrast-to-noise ratios (CNR) and image noise were measured on conventional images and VMI. Results: A total of 30 patients were included for each protocol. With iodine concentrations of 1.38±0.41 mg/mL for protocol A and 2.07±0.73 mg/mL for protocol B, the two groups were significantly different (P<0.001). No significant iodine concentration differences were found between the 16 segments (P=0.47 and P=0.09 for group A and B respectively), between basal, mid and apical segments for group A and B (P=0.28 and P=0.12 for group A and B respectively) and between wall regions for group A (P=0.06 on normalised data). In group B, iodine concentration was significantly different between three wall regions [highest values for the lateral wall, median =2.03 (1.06) mg/mL]. Post-hoc analysis showed highest contrast-to-noise and signal-to-noise in VMI at 40 eV (P<0.05). Conclusions: Iodine concentration in left ventricular myocardium of patients without significant coronary artery stenosis varied depending on the injection protocol and appeared more heterogeneous in different wall regions at faster injection rate and greater iodine load. Signal-to-noise and contrast-to-noise gradually improved when decreasing VMI energy, although at the expenses of higher noise, demonstrating the potential of DE-DLCT to enhance objective image quality.

Indexed as

Computed tomography angiography (CT angiography)dual-energy computed tomography (DECT)image enhancementiodine determinationmyocardial perfusion imaging

Identifiers

PMID35782242
PMCPMC9246727
OpenAlexW4283830034

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.