Article3D printing in medicine2022
Accuracy of guide wire placement for femoral neck stabilization using 3D printed drill guides.
Article in 3D printing in medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed, 13 citations in OpenAlex.
- Clinical efficacy of personalized 3D-printed modular navigation templates in assisting Femoral Neck System implantation for femoral neck fractures in young and middle-aged adults.BMC musculoskeletal disorders · 2025Trial
- Efficacy and factors of 3D-printed guide-assisted hollow screw internal fixation for femoral neck fractures in the elderly.Annals of medicine · 2026Article
- Improving subtalar arthrodesis with a skin-matched patient-specific surgical guide: A comparative cadaveric study.Acta orthopaedica et traumatologica turcica · 2025Article
- Guide-wire and K-wire readjustment jig for osteotomy and osteosynthesis: An instrument.Journal of clinical orthopaedics and trauma · 2025Article
- Fabricating patient-specific 3D printed drill guides to treat femoral head avascular necrosis.3D printing in medicine · 2024Article
- Evaluation of a 3D-Printed Reduction Guide for Minimally Invasive Plate Osteosynthesis of Short Oblique Radial Diaphyseal Fracture in Dogs: A Cadaveric Study.Veterinary sciences · 2024Article
- The feasibility of a novel 3D-Printed patient specific cutting guide for extended trochanteric osteotomies.3D printing in medicine · 2024Article
- Fabricating Patient-Specific 3D Printed Drill Guides to Treat Femoral Head Avascular Necrosis.Research square · 2023Article
- Medical 3D Printing Using Desktop Inverted Vat Photopolymerization: Background, Clinical Applications, and Challenges.Bioengineering (Basel, Switzerland) · 2023Review
- Patient-Specific Guides for Accurate and Precise Positioning of Osseointegrated Implants in Transfemoral Amputations: A Proof-of-Concept In Vitro Study.Medicina (Kaunas, Lithuania) · 2023Article
- Correction: Accuracy of guide wire placement for femoral neck stabilization using 3D printed drill guides.3D printing in medicine · 2022Article
- Simulating Prophylactic Fixation Methods for Osteoporotic Femoral Neck Fracture Prevention.Geriatric orthopaedic surgery & rehabilitation · 2022Article
Corrections and comments
- Erratum issued
Authors and funding
8 authors at 2 institutions in 1 country.
Funding
Abstract
backgroundThe goal of stabilization of the femoral neck is to limit morbidity and mortality from fracture. Of three potential methods of fixation, (three percutaneous screws, the Synthes Femoral Neck System, and a dynamic hip screw), each requires guide wire positioning of the implant(s) in the femoral neck and head. Consistent and accurate positioning of these systems is paramount to reduce surgical times, stabilize fractures effectively, and reduce complications. To help expedite surgery and achieve ideal implant positioning in the geriatric population, we have developed and validated a surgical planning methodology using 3D modelling and printing technology.
methodsUsing image processing software, 3D surgical models were generated placing guide wires in a virtual model of an osteoporotic proximal femur sawbone. Three unique drill guides were created to achieve the optimal position for implant placement for each of the three different implant systems, and the guides were 3D printed. Subsequently, a trauma fellowship trained orthopedic surgeon used the 3D printed guides to position 2.8 mm diameter drill bit tipped guide wires into five osteoporotic sawbones for each of the three systems (fifteen sawbones total). Computed Tomography (CT) scans were then taken of each of the sawbones with the implants in place. 3D model renderings of the CT scans were created using image processing techniques and the displacement and angular deviations at guide wire entry to the optimal sawbone model were measured.
resultsAcross all three percutaneous screw guide wires, the average displacement was 3.19 ± 0.12 mm and the average angular deviation was 4.10 ± 0.17
conclusionThe use of custom 3D printed drill guides to assist with the positioning of guide wires proved to be accurate for each of the three types of surgical strategies. Guides which are used to place more than 1 guide wire may have lower positional accuracy, as the guide may shift during multiple wire insertions. We believe that personalized point of care drill guides provide an accurate intraoperative method for positioning implants into the femoral neck.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.