Evidence map›Paper›PMID 35780699›Full record

ArticleClinical biomechanics (Bristol, Avon)2022

The addition of cerclage wiring does not improve proximal bicortical fixation of locking plates for Type C periprosthetic fractures in synthetic humeri.

Richa Gupta, Elaine C Schmidt, Surena Namdari, Michael A Stone, Michael W Hast

Open access · greenAbstract read
In one paragraph

Article in Clinical biomechanics (Bristol, Avon), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.7field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 9 citations in OpenAlex.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Richa GuptaMcKay Orthopaedic Research Laboratory, Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, PA, USA. Electronic address: richa.gupta@pennmedicine.upenn.edu.
Elaine C SchmidtMcKay Orthopaedic Research Laboratory, Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, PA, USA.
Surena NamdariRothman Orthopaedic Institute, Thomas Jefferson University, Philadelphia, PA, USA. Electronic address: surena.namdari@rothmanortho.com.
Michael A StoneRothman Orthopaedic Institute, Thomas Jefferson University, Philadelphia, PA, USA.
Michael W HastMcKay Orthopaedic Research Laboratory, Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, PA, USA. Electronic address: hast@pennmedicine.upenn.edu.
University of Pennsylvania · USThomas Jefferson University · US

Funding

Overall: Resource-based Center for Musculoskeletal Disorders Research (Overall Application)P30AR069619 · NIAMS · UNIVERSITY OF PENNSYLVANIA · PI LOUIS J SOSLOWSKY · 2016 to 2026
$9.1M
NIAMS NIH HHS P30 AR069619
6 · The paper itself

Abstract

backgroundTreatment of proximal humerus periprosthetic fractures is challenging. It remains difficult to achieve robust fixation of the proximal fragment to the locking plate using cerclage wiring and/or unicortical screws. Use of polyaxial tangentially directed bicortical locking screws increases screw purchase, but it is unclear if this option provides robust fixation. This biomechanical study compares fixation of constructs using cerclage wires, bicortical locking screws, and a hybrid method utilizing both methods.

methodsUncemented humeral stems were implanted into synthetic humeri and Type C periprosthetic fractures were simulated with a 1 cm transverse osteotomy. Distal ends of locking plates were secured with bicortical non-locking screws. The proximal ends were supported by either isolated cerclage wires, polyaxial locking screws, or a hybrid combination of both (n = 6 for each group). A universal test frame was used for non-destructive torsion and cyclic axial compression tests. 3-D motion tracking was employed to determine stiffnesses and relative interfragmentary motions.

findingsIsolated screw constructs showed significantly increased resistance against torsional movement, bending, and shear, (p < 0.05) in comparison to cerclage constructs. The hybrid construct provided no significant changes in stability over the isolated screw construct.

interpretationAddition of cerclage wires in this synthetic bone model of Type C periprosthetic humerus fractures did not add significant stability to proximal bicortical locking plate fixation. Considering risks of tissue stripping and nerve injury, usage of cerclage wires in a similar clinical setting should be chosen carefully, especially when bicortical fixation around the prosthetic stem can be achieved.

Indexed as

Periprosthetic FracturesBiomechanical PhenomenaBone PlatesFracture Fixation, InternalHumansHumerusLocking screwOsteosynthesisPeriprosthetic fractureProximal humerus

Identifiers

PMID35780699
PMCPMC10096358
OpenAlexW4283075839

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.