Evidence map›Paper›PMID 35779243›Full record

ArticleJournal of biomedical materials research. Part B, Applied biomaterials2022

A collagen/PLA hybrid scaffold supports tendon-derived cell growth for tendon repair and regeneration.

Yu Xie, Fan Zhang, Ozan Akkus, Martin W King

Abstract read
In one paragraph

Article in Journal of biomedical materials research. Part B, Applied biomaterials, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.

0numbers the graph read from it
0cells of the map it votes in
18citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

18 citing papers in PubMed.

  1. Article
  2. Review
  3. Grafts in tendon repair.Materials today. Bio · 2026
    Review
  4. Article
  5. Review
  6. Review
  7. Tendon regeneration deserves better: focused review onFrontiers in bioengineering and biotechnology · 2025
    Review
  8. Review
  9. Review
  10. Review
  11. Article
  12. Article
  13. Article
  14. Article
  15. Review
  16. Recent advances in tendon tissue engineering strategy.Frontiers in bioengineering and biotechnology · 2023
    Review
  17. A collagen/PLA hybrid scaffold supports tendon-derived cell growth for tendon repair and regeneration.Journal of biomedical materials research. Part B, Applied biomaterials · 2022
    Article
  18. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Yu XieWilson College of Textiles, North Carolina State University, Raleigh, North Carolina, USA.
Fan ZhangWilson College of Textiles, North Carolina State University, Raleigh, North Carolina, USA.ORCID 0000-0001-6754-7500
Ozan AkkusDepartment of Mechanical and Aerospace Engineering, Case Western Reserve University, Cleveland, Ohio, USA.
Martin W KingWilson College of Textiles, North Carolina State University, Raleigh, North Carolina, USA.ORCID 0000-0001-7092-0732

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A rotator cuff tendon tear is a common shoulder injury with a relatively high rate of recurrence after surgical repair. In order to reinforce the repair and reduce the risk of clinical complications, a patch scaffold is typically sutured over the tendon tear to provide post-surgical mechanical support. However, despite considerable research effort in this area, a patch scaffold that provides both superior initial mechanical properties and supports cell proliferation at the same time has not yet been achieved. In this study, we engineered a collagen/poly(lactic acid) (COL/PLA) hybrid yarn to leverage mechanical strength of PLA yarn and the bioactivity of collagen. The COL/PLA yarns were used to fabricate a tissue engineering scaffold using textile weaving technology. This hybrid scaffold had a tensile strength of 354.0 ± 36.0 N under dry conditions and 267.2 ± 15.9 N under wet conditions, which was satisfactory to maintain normal tendon function. By introducing COL yarns into the hybrid scaffold, the proliferation of tendon-derived cells was significantly improved on the scaffold. Cell coverage after 28-days of in vitro cell culture was noticeably higher on the COL yarns compared to the PLA yarns as a result of a larger number of cells and more spread cell morphology on collagen. Cells spread in multiple directions on COL yarns, which resembled a more natural cell attachment on extracellular matrix. On the contrary, the cells attached to the PLA filaments presented an elongated morphology along the fiber's axial direction. Combining the mechanical robustness of PLA and the biological activity of collagen, the woven COL/PLA hybrid scaffold has shown its potential to be a promising candidate for tendon repair applications.

Indexed as

Rotator Cuff InjuriesTissue ScaffoldsCell ProliferationCollagenHumansPolyestersRegenerationTendonsTissue EngineeringCollagenPolyestersbiomaterialsbiotextilescollagen yarntendon regenerationtissue engineering scaffold

Identifiers

PMID35779243
PMCPMC9795886

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.