Breath-dependent pressure fluctuations in various constant- and variable-flow neonatal CPAP devices.

Lorenz Auer-Hackenberg, Patricia Stroicz, Edda Hofstätter, Johannes Brandner, Clemens Haselmann, Martin Wald

Open access · hybridAbstract read
In one paragraph

Article in Pediatric pulmonology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.2field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Lorenz Auer-HackenbergDepartment of Neonatology, Division of Pediatrics and Adolescent Medicine, Paracelsus Medical Private University, Salzburg, Austria.ORCID 0000-0002-5634-5791
Patricia StroiczDepartment of Neonatology, Division of Pediatrics and Adolescent Medicine, Paracelsus Medical Private University, Salzburg, Austria.
Edda HofstätterDepartment of Neonatology, Division of Pediatrics and Adolescent Medicine, Paracelsus Medical Private University, Salzburg, Austria.
Johannes BrandnerDepartment of Neonatology, Division of Pediatrics and Adolescent Medicine, Paracelsus Medical Private University, Salzburg, Austria.
Clemens HaselmannDepartment of Neonatology, Division of Pediatrics and Adolescent Medicine, Paracelsus Medical Private University, Salzburg, Austria.
Martin WaldDepartment of Neonatology, Division of Pediatrics and Adolescent Medicine, Paracelsus Medical Private University, Salzburg, Austria.ORCID 0000-0002-6558-1032
Paracelsus Medical University · AT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveIn continuous positive airway pressure (CPAP) devices, pressure can be generated by two different mechanisms: either via an expiratory valve or by one or more jets. Valved CPAP devices are referred to as constant-flow devices, and jet devices are called variable-flow devices. Constant-flow CPAP devices are said to reduce the imposed work of breathing due to lower breath-dependent pressure fluctuations. The present study investigates the performance of various constant- and variable-flow CPAP devices in relation to breath-dependent pressure fluctuations.

designExperimental study comparing the pressure fluctuations incurred by seven neonatal CPAP devices attached to an active neonatal lung model. METHODOLOGY: Spontaneous breathing was simulated using a tidal volume of 6 ml at pressure levels of 5, 7, and 9 mbar. The main outcomes were respiratory pressure fluctuations, tidal volume, and end-expiratory pressure.

resultsAll CPAP devices tested showed respiratory pressure fluctuations, varying from 0.631 to 3.466 mbar. The generated tidal volume correlated significantly with the pressure fluctuations (r = -0.947; p = 0.001) and varied between 5.550 and 6.316 ml. CPAP devices with jets showed no advantage over CPAP devices with expiratory valves. End-expiratory pressure in the nose deviated from the set pressure between -1.305 and 0.644 mbar and varied depending on whether the pressure was measured in the device or in the tube extending to the nose.

conclusionDuring standard spontaneous breathing, breath-dependent pressure fluctuations in constant- and variable-flow devices are comparable. Pressure measurements taken in the tubing system can lead to a considerable deviation of the applied pressure.

Indexed as

Continuous Positive Airway PressureVentilators, MechanicalHumansInfant, NewbornNoseRespirationTidal Volumeconstant flownasal CPAPpressure fluctuationspreterm infantsvariable flow

Identifiers

PMID35774021
PMCPMC9796268
OpenAlexW4283756252

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.