Evidence map›Paper›PMID 35773265›Full record

ArticleLight, science & applications2022

An alternative to MINFLUX that enables nanometer resolution in a confocal microscope.

Luciano A Masullo, Alan M Szalai, Lucía F Lopez, Mauricio Pilo-Pais, Guillermo P Acuna, Fernando D Stefani

Erratum issuedOpen access · goldAbstract read
In one paragraph

Article in Light, science & applications, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 21 papers.

0numbers the graph read from it
0cells of the map it votes in
21citing papers in PubMed
13.7field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

21 citing papers in PubMed, 54 citations in OpenAlex.

  1. Nanorulers for Super-Resolution Microscopy.Chembiochem : a European journal of chemical biology · 2026
    Review
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Journal of microscopy · 2025
    Review
  11. Article
  12. Review
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 2 countries.

Luciano A MasulloCentro de Investigaciones en Bionanociencias (CIBION), Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET), Godoy Cruz 2390, C1425FQD Ciudad Autónoma de Buenos Aires, Buenos Aires, Argentina.ORCID http://orcid.org/0000-0001-8664-5448
Alan M SzalaiCentro de Investigaciones en Bionanociencias (CIBION), Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET), Godoy Cruz 2390, C1425FQD Ciudad Autónoma de Buenos Aires, Buenos Aires, Argentina.ORCID http://orcid.org/0000-0002-3795-3230
Lucía F LopezCentro de Investigaciones en Bionanociencias (CIBION), Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET), Godoy Cruz 2390, C1425FQD Ciudad Autónoma de Buenos Aires, Buenos Aires, Argentina.
Mauricio Pilo-PaisDepartment of Physics, University of Fribourg, Chemin du Musée 3, Fribourg, CH-1700, Switzerland.ORCID http://orcid.org/0000-0001-9803-7132
Guillermo P AcunaDepartment of Physics, University of Fribourg, Chemin du Musée 3, Fribourg, CH-1700, Switzerland.ORCID http://orcid.org/0000-0001-8066-2677
Fernando D StefaniCentro de Investigaciones en Bionanociencias (CIBION), Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET), Godoy Cruz 2390, C1425FQD Ciudad Autónoma de Buenos Aires, Buenos Aires, Argentina. fernando.stefani@df.uba.ar.ORCID http://orcid.org/0000-0002-3277-7215
Consejo Nacional de Investigaciones Científicas y Técnicas · ARUniversity of Fribourg · CH

Funding

Ministry of Science, Technology and Productive Innovation, Argentina | National Agency for Science and Technology, Argentina | Fondo para la Investigación Científica y Tecnológica (Fund for Scientific and Technological Research) PICT 2014-3729Ministry of Science, Technology and Productive Innovation, Argentina | National Agency for Science and Technology, Argentina | Fondo para la Investigación Científica y Tecnológica (Fund for Scientific and Technological Research) PICT 2017-0870Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung (Swiss National Science Foundation) 200021_184687
6 · The paper itself

Abstract

Localization of single fluorescent emitters is key for physicochemical and biophysical measurements at the nanoscale and beyond ensemble averaging. Examples include single-molecule tracking and super-resolution imaging by single-molecule localization microscopy. Among the numerous localization methods available, MINFLUX outstands for achieving a ~10-fold improvement in resolution over wide-field camera-based approaches, reaching the molecular scale at moderate photon counts. Widespread application of MINFLUX and related methods has been hindered by the technical complexity of the setups. Here, we present RASTMIN, a single-molecule localization method based on raster scanning a light pattern comprising a minimum of intensity. RASTMIN delivers ~1-2 nm localization precision with usual fluorophores and is easily implementable on a standard confocal microscope with few modifications. We demonstrate the performance of RASTMIN in localization of single molecules and super-resolution imaging of DNA origami structures.