Evidence map›Paper›PMID 35772938›Full record

ArticleNMR in biomedicine2022

On the design and manufacturing of miniaturized microstripline power splitters for driving multicoil transmit arrays with arbitrary ratios at 7 T.

Charlotte R Sappo, Gabriela L Gallego, William A Grissom, Xinqiang Yan

Abstract read
In one paragraph

Article in NMR in biomedicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Charlotte R SappoVanderbilt University Institute of Imaging Science, Nashville, Tennessee, USA.ORCID 0000-0002-7030-278X
Gabriela L GallegoDepartment of Electrical and Computer Engineering, Vanderbilt University, Nashville, Tennessee, USA.
William A GrissomVanderbilt University Institute of Imaging Science, Nashville, Tennessee, USA.
Xinqiang YanVanderbilt University Institute of Imaging Science, Nashville, Tennessee, USA.

Funding

MRI CORTICOGRAPHY: DEVELOPING NEXT GENERATION MICROSCALE HUMAN CORTEX MRI SCANNERU01EB025162 · NIBIB · UNIVERSITY OF CALIFORNIA BERKELEY · PI FEINBERG, DAVID ALAN, LIU, CHUNLEI · 2017 to 2021
$13.4M
Three-Dimensional Patient-Tailored RF Pulses for Spin Echo Neuroimaging at 7 TR01EB016695 · NIBIB · VANDERBILT UNIVERSITY · PI GRISSOM, WILLIAM A · 2014 to 2021
$3.8M
NIBIB NIH HHS R01 EB016695NIBIB NIH HHS U01 EB025162
6 · The paper itself

Abstract

The purpose of the current study was to implement unequal microstrip power splitters for parallel transmission at 7 T that are optimized for size and loss and that can be configured for a wide range of power ratios. The splitters will enable the use of more transmit coils without a corresponding increase in the number of transmit channels or amplifiers to control specific absorption rate, shorten RF pulses, and shim inhomogeneous RF fields. Wilkinson unequal power splitters based on a novel microstrip network design were optimized to minimize their size under 8 cm in length and 9 cm in width, enabling them to be included in coil housing or cascaded in multiple stages. Splitters were designed and constructed for a wide range of output power ratios at 298 MHz. Simulations and bench tests were performed for each ratio, and a methodology was established to adapt the designs to other ratios and frequencies. The designs and code are open source and can be reproduced as is or reconfigured. The single-stage designs achieved good matches and isolations between output ports (worst isolation -15.9 dB, worst match -15.1 dB). A two-stage cascaded (one input to four outputs) power splitter with 1:2.5, 1:10, 1:3, and 1:6 ratio outputs was constructed. The worst isolation between output ports was -19.7 dB in simulation and the worst match of the three ports was -17.8 dB. The measured ratios for one- and two-stage boards were within 10% of the theoretical ratios. The power-handling capability of the smallest trace was approximately 70 W. Power loss for the one- and two-stage boards ranged from 1% to 3% in simulation compared with 5.1% to 7.2% on the bench. It was concluded that Wilkinson unequal microstrip power splitters can be implemented with a small board size (low height) and low loss, and across a wide range of output power ratios. The splitters can be cascaded in multiple stages while maintaining the expected ratios and low loss. This will enable the construction of large fixed transmit array-compression matrices with low loss.

Indexed as

Data CompressionMagnetic Resonance ImagingAmplifiers, ElectronicComputer SimulationEquipment DesignPhantoms, Imagingarray compressionminiaturizationMR engineeringoptimizationparallel transmissionplanar transmission lineRF coilsultra-high field MRI

Identifiers

PMID35772938
PMCPMC11193150

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.