Evidence map›Paper›PMID 35771002›Full record

ArticleMolecular imaging and radionuclide therapy2022

Comparison of the Diagnostic Performance of Myocardial Perfusion Scintigraphy with and Without Attenuation Correction.

Sira Vachatimanont, Sasitorn Sirisalipoch, Maythinee Chantadisai

Open access · diamondAbstract read
In one paragraph

Article in Molecular imaging and radionuclide therapy, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.9field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 1 country.

Sira VachatimanontChulalongkorn University and King Chulalongkorn Memorial Hospital, Department of Radiology, Division of Nuclear Medicine, Bangkok, Thailand.ORCID 0000-0002-7393-2250
Sasitorn SirisalipochChulalongkorn University and King Chulalongkorn Memorial Hospital, Department of Radiology, Division of Nuclear Medicine, Bangkok, Thailand.ORCID 0000-0002-5313-5393
Maythinee ChantadisaiChulalongkorn University and King Chulalongkorn Memorial Hospital, Department of Radiology, Division of Nuclear Medicine, Bangkok, Thailand.ORCID 0000-0003-1691-3958
Chulalongkorn University · THThai Red Cross Society · TH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objectives: Myocardial perfusion scintigraphy (MPS) is an important diagnostic test for detecting of coronary artery stenosis (CAS); however, tissue attenuation can lead to a difference in accuracy. We evaluated the diagnostic accuracy of attenuation-corrected (AC) and non-attenuation-corrected (NC) MPS for the detection of CAS. Methods: We retrospectively recruited patients who underwent invasive coronary angiography within 10 months after Tc-99m sestamibi MPS. The AC and NC perfusion images were analyzed separately, and each myocardial segment was scored based on relative uptake from 0 to 4. The summed stress score (SSS), summed rest score (SRS), and summed difference score (SDS) were calculated. The diagnostic performances were analyzed using the area under the curve (AUC) of the receiver operating characteristic curve. Results: From 117 patients, significant coronary stenosis was present in 66 patients (56%). The SSS and SRS obtained from NC-images were higher than those from AC, supporting the presence of attenuation artifacts in NC images. The AUC of SSS and SDS were significantly higher than those of SRS in both AC- and NC-images, but no significant difference was found between the AUC of SSS, and those of SDS. The optimal cut-offs were >12 for AC-SSS, >15 for NC-SSS, >4 for AC-SDS and >3 for NC-SDS. There was no statistically significant difference in the sensitivity, specificity, positive predictive value, negative predictive value, and accuracy among AC-SSS, NC-SSS, AC-SDS, and NC-SDS. Conclusion: NC-based Tc-99m-sestamibi MPS promised comparable accuracy to AC images by using different cut-off values for diagnosis.

Indexed as

accuracyattenuation correctionCoronary artery diseasediagnostic performancemyocardial perfusion imagingsingle photon emission computed tomography

Identifiers

PMID35771002
PMCPMC9246313
OpenAlexW4283650067

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked