ArticleFrontiers in cardiovascular medicine2022
A 3-Year Single Center Experience With Left Atrial Pressure Remote Monitoring: The Long and Winding Road.
Article in Frontiers in cardiovascular medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT03775161 (A First in Human Multi-center, Open Label, Prospective Study to Evaluate the Safety, Usability and Performance of the V-LAP™ System), which is not on this map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
A First in Human Multi-center, Open Label, Prospective Study to Evaluate the Safety, Usability and Performance of the V-LAP™ System
Who cites it
5 citing papers in PubMed, 8 citations in OpenAlex.
- Baseline characteristics of patients enrolled in the AZIMUTH trial: an e-health-integrated, smartphone app-based model of care for heart failure patients.European heart journal open · 2026Article
- Study design and rationale of the AZIMUTH trial: a smartphone, app-based, E-health-integrated model of care for heart failure patients.European heart journal. Digital health · 2025Article
- Device-based Strategies for Monitoring Congestion and Guideline-directed Therapy in Heart Failure: The Who, When and How of Personalised Care.Cardiac failure review · 2025Review
- Current Approaches to Worsening Heart Failure: Pathophysiological and Molecular Insights.International journal of molecular sciences · 2024Review
- Noninvasive Hemodynamic Monitoring in Advanced Heart Failure Patients: New Approach for Target Treatments.Biomedicines · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
13 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Despite continuous advancement in the field, heart failure (HF) remains the leading cause of hospitalization among the elderly and the overall first cause of hospital readmission in developed countries. Implantable hemodynamic monitoring is being tested to anticipate the clinical exacerbation onset, potentially preventing an emergent acute decompensation. To date, only pulmonary artery pressure (PAP) sensor received the approval to be implanted in symptomatic heart failure patients with reduced ejection fraction. However, PAP's indirect estimation of left ventricular filling pressure can be inaccurate in some contexts. Methods: The VECTOR-HF study (NCT03775161) is examining the safety, usability and performance of the V-LAP system, a latest-generation device capable of continuously monitoring left atrial pressure (LAP). In our center, five advanced HF patients have been enrolled. After confirmation of the transmitted data reliability, LAP trends and waveforms have guided therapy optimization. The aim of this work is to share clinical insights from our center preliminary experience with V-LAP application. Results: Over a median follow-up time of 18 months, LAP-based therapy optimization managed to reduce intracardiac pressure over time and no hospital readmission occurred. This result was paralleled by an improvement in both functional capacity (6MWT distance 352.5 ± 86.2 meters at baseline to 441.2 ± 125.2 meters at last follow-up) and quality of life indicators (KCCQ overall score 63.82 ± 16.36 vs. 81.92 ± 9.63; clinical score 68.47 ± 19.48 vs. 83.70 ± 15.58). Conclusion: Preliminary evidence from V-LAP application at our institution support a promising efficacy. However, further study is needed to confirm the technical reliability of the device and to exploit the clinical benefit of left-sided hemodynamic remote monitoring.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.