Evidence map›Paper›PMID 35769707›Full record

ArticleFrontiers in neuroscience2022

The Long-Term Stability of Intracortical Microstimulation and the Foreign Body Response Are Layer Dependent.

Morgan E Urdaneta, Nicolas G Kunigk, Seth Currlin, Francisco Delgado, Shelley I Fried, Kevin J Otto

Open access · goldAbstract read
In one paragraph

Article in Frontiers in neuroscience, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers.

0numbers the graph read from it
0cells of the map it votes in
17citing papers in PubMed
2.2field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

17 citing papers in PubMed, 24 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Stability Assessment of Ultramicroelectrode Arrays in Neural Stimulation: an Electrochemical Impedance Spectroscopy Analysis.Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2024
    Article
  8. The Effect of Physical Structural Properties on Electrochemical Properties of Ruthenium Oxide for Neural Stimulating and Recording Electrodes.Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2024
    Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Morgan E UrdanetaDepartment of Neuroscience, University of Florida, Gainesville, FL, United States.
Nicolas G KunigkJ. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL, United States.
Seth CurrlinDepartment of Neuroscience, University of Florida, Gainesville, FL, United States.
Francisco DelgadoJ. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, FL, United States.
Shelley I FriedDepartment of Neurosurgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, United States.
Kevin J OttoDepartment of Neuroscience, University of Florida, Gainesville, FL, United States.
University of Florida · USVA Boston Healthcare System · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Intracortical microstimulation (ICMS) of the somatosensory cortex (S1) can restore sensory function in patients with paralysis. Studies assessing the stability of ICMS have reported heterogeneous responses across electrodes and over time, potentially hindering the implementation and translatability of these technologies. The foreign body response (FBR) and the encapsulating glial scar have been associated with a decay in chronic performance of implanted electrodes. Moreover, the morphology, intrinsic properties, and function of cells vary across cortical layers, each potentially affecting the sensitivity to ICMS as well as the degree of the FBR across cortical depth. However, layer-by-layer comparisons of the long-term stability of ICMS as well as the extent of the astrocytic glial scar change across cortical layers have not been well explored. Here, we implanted silicon microelectrodes with electrode sites spanning all the layers of S1 in rats. Using a behavioral paradigm, we obtained ICMS detection thresholds from all cortical layers for up to 40 weeks. Our results showed that the sensitivity and long-term performance of ICMS is indeed layer dependent. Overall, detection thresholds decreased during the first 7 weeks post-implantation (WPI). This was followed by a period in which thresholds remained stable or increased depending on the interfacing layer: thresholds in L1 and L6 exhibited the most consistent increases over time, while those in L4 and L5 remained the most stable. Furthermore, histological investigation of the tissue surrounding the electrode showed a biological response of microglia and macrophages which peaked at L1, while the area of the astrocytic glial scar peaked at L2/3. Interestingly, the biological response of these FBR markers is less exacerbated at L4 and L5, suggesting a potential link between the FBR and the long-term stability of ICMS. These findings suggest that interfacing depth can play an important role in the design of chronically stable implantable microelectrodes.

Indexed as

brain computer interfacecortexforeign body response (FBR)glial scarmicroelectrode arraymicroglianeuroprostheses

Identifiers

PMID35769707
PMCPMC9234554
OpenAlexW4282836849

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked