Evidence map›Paper›PMID 35768457›Full record

ArticleScientific reports2022

Foot contact forces can be used to personalize a wearable robot during human walking.

Michael Jacobson, Prakyath Kantharaju, Hyeongkeun Jeong, Jae-Kwan Ryu, Jung-Jae Park, Hyun-Joon Chung, Myunghee Kim

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
2.0field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 24 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 2 countries.

Michael Jacobson *University of Illinois at Chicago, Mechanical and Industrial Engineering, Chicago, 60607, USA.
Prakyath Kantharaju *University of Illinois at Chicago, Mechanical and Industrial Engineering, Chicago, 60607, USA.
Hyeongkeun JeongUniversity of Illinois at Chicago, Mechanical and Industrial Engineering, Chicago, 60607, USA.
Jae-Kwan RyuLIG Nex1, Seongnam, 13488, South Korea.
Jung-Jae ParkLIG Nex1, Seongnam, 13488, South Korea.
Hyun-Joon ChungKorea Institute of Robotics and Technology Convergence, Pohang, South Korea.
Myunghee KimUniversity of Illinois at Chicago, Mechanical and Industrial Engineering, Chicago, 60607, USA. myheekim@uic.edu.
University of Illinois Chicago · USGS Caltex (South Korea) · KRKorea Institute of Robot and Convergence · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Individuals with below-knee amputation (BKA) experience increased physical effort when walking, and the use of a robotic ankle-foot prosthesis (AFP) can reduce such effort. The walking effort could be further reduced if the robot is personalized to the wearer using human-in-the-loop (HIL) optimization of wearable robot parameters. The conventional physiological measurement, however, requires a long estimation time, hampering real-time optimization due to the limited experimental time budget. This study hypothesized that a function of foot contact force, the symmetric foot force-time integral (FFTI), could be used as a cost function for HIL optimization to rapidly estimate the physical effort of walking. We found that the new cost function presents a reasonable correlation with measured metabolic cost. When we employed the new cost function in HIL ankle-foot prosthesis stiffness parameter optimization, 8 individuals with simulated amputation reduced their metabolic cost of walking, greater than 15% (p < 0.02), compared to the weight-based and control-off conditions. The symmetry cost using the FFTI percentage was lower for the optimal condition, compared to all other conditions (p < 0.05). This study suggests that foot force-time integral symmetry using foot pressure sensors can be used as a cost function when optimizing a wearable robot parameter.

Indexed as

Artificial LimbsWearable Electronic DevicesAnkle JointBiomechanical PhenomenaGaitHumansWalking

Identifiers

PMID35768457
PMCPMC9243054
OpenAlexW4283699904

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.