Evidence map›Paper›PMID 35767709›Full record

ArticleUltrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology2023

Role of fetal head-circumference-to-maternal-height ratio in predicting Cesarean section for labor dystocia: prospective multicenter study.

A Dall'Asta, R Ramirez Zegarra, E Corno, I Mappa, J L A Lu, E Di Pasquo, G Morganelli, M Abou-Dakn, C Germano, R Attini and 3 more

Open access · hybridAbstract readMulticenter Study
In one paragraph

Article in Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
2.0field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 12 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors at 4 institutions in 2 countries.

A Dall'AstaDepartment of Medicine and Surgery, Obstetrics and Gynecology Unit, University of Parma, Parma, Italy.ORCID 0000-0001-7201-0206
R Ramirez ZegarraDepartment of Medicine and Surgery, Obstetrics and Gynecology Unit, University of Parma, Parma, Italy.ORCID 0000-0001-7706-3016
E CornoDepartment of Medicine and Surgery, Obstetrics and Gynecology Unit, University of Parma, Parma, Italy.
I MappaDepartment of Obstetrics and Gynecology, Fondazione Policlinico Tor Vergata, University of Rome Tor Vergata, Rome, Italy.
J L A LuDepartment of Obstetrics and Gynecology, Fondazione Policlinico Tor Vergata, University of Rome Tor Vergata, Rome, Italy.ORCID 0000-0002-5962-2846
E Di PasquoDepartment of Medicine and Surgery, Obstetrics and Gynecology Unit, University of Parma, Parma, Italy.ORCID 0000-0002-4405-4188
G MorganelliDepartment of Medicine and Surgery, Obstetrics and Gynecology Unit, University of Parma, Parma, Italy.
M Abou-DaknDepartment of Obstetrics and Gynecology, St Joseph Krankenhaus, Berlin, Germany.
C GermanoDepartment of Obstetrics and Gynecology, Sant'Anna Hospital, University of Turin, Turin, Italy.
R AttiniDepartment of Obstetrics and Gynecology, Sant'Anna Hospital, University of Turin, Turin, Italy.
B MasturzoDepartment of Obstetrics and Gynecology, Sant'Anna Hospital, University of Turin, Turin, Italy.
G RizzoDepartment of Obstetrics and Gynecology, Fondazione Policlinico Tor Vergata, University of Rome Tor Vergata, Rome, Italy.ORCID 0000-0002-5525-4353
T GhiDepartment of Medicine and Surgery, Obstetrics and Gynecology Unit, University of Parma, Parma, Italy.ORCID 0000-0003-1823-1096
University of Parma · ITOspedale Sant'Anna · ITUniversity of Rome Tor Vergata · ITSt. Joseph-Krankenhaus · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo evaluate the relationship between the fetal head-circumference-to-maternal-height (HC/MH) ratio measured shortly before delivery and the occurrence of Cesarean section (CS) for labor dystocia.

methodsThis was a multicenter prospective cohort study involving four tertiary maternity hospitals. An unselected cohort of women with a singleton fetus in cephalic presentation, at a gestational age beyond 36 + 0 weeks and without any contraindication for vaginal delivery, was enrolled between September 2020 and November 2021. The MH and fetal HC were measured on admission of the patient to the labor ward. The primary outcome of the study was the performance of the HC/MH ratio in the prediction of CS for labor dystocia. Women who underwent CS for any indication other than failed labor progression, including fetal distress, were excluded from the final analysis.

resultsA total of 783 women were included in the study. Vaginal delivery occurred in 744 (95.0%) women and CS for labor dystocia in 39 (5.0%). CS for labor dystocia was associated with shorter MH (mean ± SD, 160.4 ± 6.6 vs 164.5 ± 6.3 cm; P < 0.001), larger fetal HC (339.6 ± 9.5 vs 330.7 ± 13.0 mm; P < 0.001) and a higher HC/MH ratio (2.12 ± 0.11 vs 2.01 ± 0.10; P < 0.001) compared with vaginal delivery. Multivariate logistic regression analysis showed that the HC/MH ratio was associated independently with CS for labor dystocia (adjusted odds ratio, 2.65 (95% CI, 1.85-3.79); P < 0.001). The HC/MH ratio had an area under the receiver-operating-characteristics curve of 0.77 and an optimal cut-off value for discriminating between vaginal delivery and CS for labor dystocia of 2.09, which was associated with a sensitivity of 0.62 (95% CI, 0.45-0.77), specificity of 0.79 (95% CI, 0.76-0.82), positive predictive value of 0.13 (95% CI, 0.09-0.19) and negative predictive value of 0.98 (95% CI, 0.96-0.99).

conclusionsIn a large cohort of unselected pregnancies, the HC/MH ratio performed better than did fetal HC and MH alone in identifying those cases that will undergo CS for labor dystocia, albeit with moderate predictive value. The HC/MH ratio could assist in the evaluation of women at risk for CS for labor dystocia. © 2022 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.

Indexed as

DystociaLabor, ObstetricCesarean SectionFemaleHumansInfantMalePregnancyProspective StudiesUltrasonography, PrenatalCesarean sectionhead circumferencelabor dystociamaternal heightvaginal delivery

Identifiers

PMID35767709
PMCPMC10107777
OpenAlexW4283741834

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.