Evidence map›Paper›PMID 35766450›Full record

ArticleMagnetic resonance in medicine2022

Multi-echo quantitative susceptibility mapping: how to combine echoes for accuracy and precision at 3 Tesla.

Emma Biondetti, Anita Karsa, Francesco Grussu, Marco Battiston, Marios C Yiannakas, David L Thomas, Karin Shmueli

Open access · hybridAbstract read
In one paragraph

Article in Magnetic resonance in medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
1.6field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 11 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Review
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 4 institutions in 3 countries.

Emma BiondettiInstitute for Advanced Biomedical Technologies, Department of Neuroscience, Imaging and Clinical Sciences, "D'Annunzio University" of Chieti-Pescara, Chieti, Italy.ORCID 0000-0001-6727-0935
Anita KarsaDepartment of Medical Physics and Biomedical Engineering, University College London, London, United Kingdom.ORCID 0000-0002-8648-3853
Francesco GrussuNMR Research Unit, Queen Square MS Centre, Department of Neuroinflammation, UCL Queen Square Institute of Neurology, University College London, London, United Kingdom.ORCID 0000-0002-0945-3909
Marco BattistonNMR Research Unit, Queen Square MS Centre, Department of Neuroinflammation, UCL Queen Square Institute of Neurology, University College London, London, United Kingdom.ORCID 0000-0003-2231-2251
Marios C YiannakasNMR Research Unit, Queen Square MS Centre, Department of Neuroinflammation, UCL Queen Square Institute of Neurology, University College London, London, United Kingdom.ORCID 0000-0003-4986-446X
David L ThomasDementia Research Centre, UCL Queen Square Institute of Neurology, University College London, London, United Kingdom.
Karin ShmueliDepartment of Medical Physics and Biomedical Engineering, University College London, London, United Kingdom.ORCID 0000-0001-7520-2975
Queen Mary University of London · GBUniversity College London · GBUniversity of Chieti-Pescara · ITWellcome Centre for Human Neuroimaging · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo compare different multi-echo combination methods for MRI QSM. Given the current lack of consensus, we aimed to elucidate how to optimally combine multi-echo gradient-recalled echo signal phase information, either before or after applying Laplacian-base methods (LBMs) for phase unwrapping or background field removal.

methodsMulti-echo gradient-recalled echo data were simulated in a numerical head phantom, and multi-echo gradient-recalled echo images were acquired at 3 Tesla in 10 healthy volunteers. To enable image-based estimation of gradient-recalled echo signal noise, 5 volunteers were scanned twice in the same session without repositioning. Five QSM processing pipelines were designed: 1 applied nonlinear phase fitting over TEs before LBMs; 2 applied LBMs to the TE-dependent phase and then combined multiple TEs via either TE-weighted or SNR-weighted averaging; and 2 calculated TE-dependent susceptibility maps via either multi-step or single-step QSM and then combined multiple TEs via magnitude-weighted averaging. Results from different pipelines were compared using visual inspection; summary statistics of susceptibility in deep gray matter, white matter, and venous regions; phase noise maps (error propagation theory); and, in the healthy volunteers, regional fixed bias analysis (Bland-Altman) and regional differences between the means (nonparametric tests).

resultsNonlinearly fitting the multi-echo phase over TEs before applying LBMs provided the highest regional accuracy of

conclusionFor multi-echo QSM, we recommend combining the signal phase by nonlinear fitting before applying LBMs.

Indexed as

Magnetic Resonance ImagingWhite MatterBrainBrain MappingHumansImage Processing, Computer-AssistedPhantoms, ImagingMRImulti-echo QSMquantitative susceptibility mapping

Identifiers

PMID35766450
PMCPMC9545116
OpenAlexW4283719622

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.