ArticleKorean journal of ophthalmology : KJO2022

Agreement between Two Swept-Source Optical Coherence Tomography Biometers and a Partial Coherence Interferometer.

Ji Young Moon, Soo Chang Cho, Hyun Jin Kim, Roo Min Jun, Kyung Eun Han

Abstract read
In one paragraph

Article in Korean journal of ophthalmology : KJO, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Ji Young MoonDepartment of Ophthalmology, Ewha Womans University Mokdong Hospital, Ewha Womans University School of Medicine, Seoul, Korea.
Soo Chang ChoDepartment of Ophthalmology, Ewha Womans University Mokdong Hospital, Ewha Womans University School of Medicine, Seoul, Korea.
Hyun Jin KimDepartment of Ophthalmology, Ewha Womans University Mokdong Hospital, Ewha Womans University School of Medicine, Seoul, Korea.
Roo Min JunDepartment of Ophthalmology, Ewha Womans University Seoul Hospital, Ewha Womans University School of Medicine, Seoul, Korea.
Kyung Eun HanDepartment of Ophthalmology, Ewha Womans University Mokdong Hospital, Ewha Womans University School of Medicine, Seoul, Korea.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo evaluate the level of agreement between ANTERION (Heidelberg Engineering, Heidelberg, Germany), OA-2000 (Tomey, Nagoya, Japan), and IOLMaster 500 (Carl Zeiss AG, Jena, Germany).

methodsFifty-one eyes of 51 patients were included in the study. Flat keratometry (K) and steep K, vector component of astigmatism (Jackson cross-cylinder at 0° and 90° [J0] and Jackson cross-cylinder at 45° and 135° [J45]), anterior chamber depth, and axial length were compared using the three devices. Repeated measures analysis of variance was conducted to compare the mean values of the biometrics. Pearson correlation test was conducted to analyze the correlations of the measured values, and a Bland-Altman plot was used to assess the agreement between the three devices. The predicted intraocular lens power of each device was compared to the others using the SRK/T, Haigis, Barrett Universal II, and Kane formulas.

resultsAll K values measured using ANTERION were flatter than those of other instruments. However, good agreement was observed for flat K (ANTERION - OA-2000; 95% limits of agreement [LoA], 0.86 diopters [D]) and steep K (ANTERION - OA2000; 95% LoA, 0.93 D) and OA-2000 - IOLMaster 500 (95% LoA, 0.93 D). J0 and J45 vector components of astigmatism were not statistically different; however, the agreements were poor between the devices (95% LoA ≥1.97 D). Anterior chamber depth values of ANTERION and OA-2000 were interchangeable (95% LoA, 0.15 mm). The axial length showed a high agreement (95% LoA ≤0.17 mm) among the three devices. The predicted intraocular lens powers of the three devices were not interchangeable regardless of formulas (95% LoA ≥1.04 D).

conclusionsSignificant differences in ocular biometrics were observed between ANTERION and the other two devices. This study demonstrated that only axial length showed good agreement among devices.

Indexed as

AstigmatismLenses, IntraocularAnterior ChamberAxial Length, EyeBiometryCorneaHumansProspective StudiesReproducibility of ResultsTomography, Optical CoherenceBiometryPartial coherence interferometerSwept-source optical coherence tomography

Identifiers

PMID35766049
PMCPMC9388892

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.