Evidence map›Paper›PMID 35764819›Full record

ArticleCardiovascular and interventional radiology2022

Pilot Animal Study on Robotic-Assisted Endovascular Visceral Interventions.

Patrick A Kupczyk, Ulrike I Attenberger, Carsten Meyer, Julian A Luetkens, Daniel Kuetting

Open access · hybridAbstract read
In one paragraph

Article in Cardiovascular and interventional radiology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.9field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Patrick A KupczykDepartment of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany. patrick.kupczyk@ukbonn.de.ORCID http://orcid.org/0000-0001-9556-085X
Ulrike I AttenbergerDepartment of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany.
Carsten MeyerDepartment of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany.
Julian A LuetkensDepartment of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany.
Daniel KuettingDepartment of Diagnostic and Interventional Radiology, University Hospital Bonn, Venusberg-Campus 1, 53127, Bonn, Germany.
University Hospital Bonn · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo evaluate technical feasibility and safety of common endovascular visceral interventions using a vascular robotic platform through preclinical study. MATERIAL AND

methodsThe CorPath GRX Robotic System (Corindus Inc, Waltham, Massachusetts) was tested in an anesthetized pig for its ability to navigate various commercially available devices in the abdominal vasculature and to perform routine endovascular visceral procedures. After manually placing a guiding catheter in the celiac trunk, several visceral branches were probed with microcatheters and -wires under robotic assistance, and embolization with liquids (lipiodol), detachable coils and plugs were performed. Furthermore, the origin of the celiac trunk was stented before accessing the left hypogastric artery for pelvic embolization.

resultsAll procedures were performed with technical success and without any complications. Navigating the catheters and wires via the steering console proved intuitive. Coil, plug and stent deployment were exclusively controlled by remote with remarkable precision and stability.

conclusionRobotic-assisted visceral embolization and stenting as well as pelvic embolization using the CorPath GRX System is feasible and safe. Application of the platform in the abdominal vasculature is demonstrated for the first time. Considering the precision and the potential for reducing the operator's radiation exposure, further research in this area is highly encouraged to enable translation into clinical practice.

Indexed as

Endovascular ProceduresRobotic Surgical ProceduresAnimalsFeasibility StudiesStentsSwineTreatment OutcomeEmbolizationEndovascularRoboticsStentingVisceral

Identifiers

PMID35764819
PMCPMC9307548
OpenAlexW4283703424

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.