Evidence map›Paper›PMID 35764694›Full record

ArticleActa neurochirurgica2022

Evaluation of the precision of navigation-assisted endoscopy according to the navigation tool setup and the type of endoscopes.

Lara Chavaz, Alioucha Davidovic, Torstein R Meling, Shahan Momjian, Karl Schaller, Philippe Bijlenga, Julien Haemmerli

Abstract read
In one paragraph

Article in Acta neurochirurgica, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Lara ChavazFaculty of Medicine, University of Geneva, Geneva, Switzerland.
Alioucha DavidovicFaculty of Medicine, University of Geneva, Geneva, Switzerland.
Torstein R MelingFaculty of Medicine, University of Geneva, Geneva, Switzerland.
Shahan MomjianFaculty of Medicine, University of Geneva, Geneva, Switzerland.
Karl SchallerFaculty of Medicine, University of Geneva, Geneva, Switzerland.
Philippe BijlengaFaculty of Medicine, University of Geneva, Geneva, Switzerland.
Julien HaemmerliDivision of Neurosurgery, Department of Clinical Neurosciences, Geneva University Hospitals, Rue Gabrielle-Perret-Gentil 4, 1205, Geneva, Switzerland. Julien.haemmerli@hcuge.ch.ORCID http://orcid.org/0000-0001-7446-3815

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectPreoperative image-based neuronavigation-assisted endoscopy during intracranial procedures is gaining great interest. This study aimed to analyze the precision of navigation-assisted endoscopy according to the navigation setup, the type of optic and its working angulation.

methodsA custom-made box with four screws was referenced. The navigation-assisted endoscope was aligned on the screws (targets). The precision on the navigation screen was defined as the virtual distance-to-target between the tip of the endoscope and the center of the screws. Three modifiers were assessed: (1) the distance D between the box and the reference array (CLOSE 13 cm - MIDDLE 30 cm - FAR 53 cm), (2) the distance between the tip of the endoscope and the navigation array on the endoscope (close 5 cm - middle 10 cm - far 20 cm), (3) the working angulation of the endoscope (0°-endoscope and 30°-endoscope angled at 90° and 45° with the box).

resultsThe median precision was 1.3 mm (Q1: 1.1; Q3: 1.7) with the best setting CLOSE/close. The best setting in surgical condition (CLOSE/far) showed a distance-to-target of 2.3 mm (Q1: 1.9; Q3: 2.5). The distance D was correlated to the precision (Spearman rho = 0.82), but not the distance d (Spearman rho = 0.04). The type of optic and its angulation with the box were also correlated to the precision (Spearman rho =  - 0.37). The best setting was the use of a 30°-endoscope angled at 45° (1.4 mm (Q1: 1.0; Q3: 1.9)).

conclusionNavigated-assisted endoscopy is feasible and offers a good precision. The navigation setup should be optimized, reducing the risk of inadvertent perifocal damage.

Indexed as

EndoscopesNeuronavigationEndoscopyHumansEndoscopyNavigation-assisted endoscopyNeuroendoscopyNeuronavigationNeurosurgery

Identifiers

PMID35764694
PMCPMC9427865

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.