Evidence map›Paper›PMID 35764217›Full record

ArticleMagnetic resonance imaging2022

Mapping pH using stimulated echoes formed via chemical exchange.

Yu Zhao, Zhongliang Zu, Junzhong Xu, John C Gore, Mark D Does, Jianqi Li, Daniel F Gochberg

Abstract read
In one paragraph

Article in Magnetic resonance imaging, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Yu ZhaoVanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA; Shanghai Key Laboratory of Magnetic Resonance, School of Physics and Electronic Science, East China Normal University, Shanghai, China.
Zhongliang ZuVanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA.
Junzhong XuVanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA.
John C GoreVanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA.
Mark D DoesVanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA.
Jianqi LiShanghai Key Laboratory of Magnetic Resonance, School of Physics and Electronic Science, East China Normal University, Shanghai, China.
Daniel F GochbergVanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA. Electronic address: daniel.gochberg@vanderbilt.edu.

Funding

CERT Imaging of CancerR01CA184693 · NCI · VANDERBILT UNIVERSITY MEDICAL CENTER · PI GOCHBERG, DANIEL F · 2014 to 2018
$1.6M
CERT Imaging of MuscleR01EB017767 · NIBIB · VANDERBILT UNIVERSITY MEDICAL CENTER · PI GOCHBERG, DANIEL F · 2014 to 2017
$1.4M
NCI NIH HHS R01 CA184693NIBIB NIH HHS R01 EB017767
6 · The paper itself

Abstract

purposeRACETE (refocused acquisition of chemical exchange transferred excitations) is a recently developed approach to imaging solute exchange with water. However, it lacks biophysical specificity, as it is sensitive to exchange rates, relaxation rates, solute concentration, and macromolecular content. We modified this sequence and developed a protocol and corresponding metric with specific sensitivity to the solute exchange rate and hence a means for mapping pH. THEORY AND

methodsRACETE splits the two gradients traditionally used in a stimulated-echo sequence into one applied after exciting solutes and one applied after exciting water, hence requiring exchange for echo formation. In this work, we leverage the dependence of the stimulated-echo signal on the exchange process. By preserving the total irradiation power and using a ratio metric, the other signal dependencies cancel, leaving a specific measure of exchange rate. Additionally, artifacts due to off-resonance excitation of water are addressed using a phase cancelling approach; and a gradient-echo imaging sequence with a variable flip angle excitation is tailored for a fast read-out of RECETE prepared signals. This method is validated using numerical simulations and salicylic acid phantom experiments at 9.4 T.

resultsNumerical simulations and phantom experiments demonstrate that the ratio-metric is a single-variable function of exchange rate with extremely low dependence on confounding factors. Additionally, artifacts due to direct water excitation are removed and robustness to B0 and B1 inhomogeneities is demonstrated.

conclusionThe proposed method can be used for fast pH mapping with robustness against the confounding effects that widely exist in other methods.

Indexed as

Magnetic Resonance ImagingWaterHydrogen-Ion ConcentrationPhantoms, ImagingReproducibility of ResultsWaterChemical exchangepH mappingRatio metricStimulated echo

Identifiers

PMID35764217
PMCPMC12951639

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.