ArticleEuropean journal of orthopaedic surgery & traumatology : orthopedie traumatologie2023
Does stress shielding after radial head arthroplasty affect functional outcomes?
Article in European journal of orthopaedic surgery & traumatology : orthopedie traumatologie, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed, 1 synthesis or guideline pooled it, 8 citations in OpenAlex.
- Uncementing the status quo: systematic review of a loose-fit, polished stem radial head prosthesis shows stable clinical results in complex elbow injuries with a concomitant radial head fracture.Journal of orthopaedic surgery and research · 2024Pooled it
- Good outcomes of bipolar radial head arthroplasty for comminuted radial head fractures : a cohort study of 64 patients with an average 5.2-year follow-up.Bone & joint open · 2025Article
- Experimental Analysis of Stress Shielding Effects in Screw Spacers Placed in Porcine Spinal Tissue.Journal of functional biomaterials · 2024Article
- Stress Shielding around Press-Fit Radial Head Arthroplasty: Proposal for a New Classification System Based on the Analysis of 97 Patients with a Mid-Term Follow-Up and a Review of the Literature.Healthcare (Basel, Switzerland) · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundVarious complications related to the prosthesis, such as implant loosening and stress shielding phenomenon, could develop after prosthetic replacement of the radial head. Stress shielding is known to occur around rigidly fixed implants. The purpose of this study was to evaluate the clinical influence and causative factors of the stress shielding phenomenon after radial head arthroplasty (RHA).
methodsClinical records and radiographs of 56 patients with unreconstructable radial head fractures who received radial head replacement between 2009 and 2019 were reviewed. Exclusion criteria were infection, loosening, and follow-up of less than 24 months. After exclusion, 35 patients were enrolled. Patients were divided into two groups: an anatomical press-fit group (Anatomical Radial Head System; Acumed, Hillsboro, OR, USA) and a round bipolar cemented group (RHS; Tornier, Montbonnot Saint-Martin, France). Stress shielding around the prosthesis was assessed in the serial radiological examination. Clinical results were assessed using Mayo elbow performance score (MEPS), Quick Disabilities of the Arm, Shoulder, and Hand (q-DASH) score, range of motion (flexion-extension arc and pronation-supination arc), and visual analog scale score (VAS). Correlations between stress shielding phenomenon and demographic data and functional results were analyzed.
resultsAt an average follow-up of 43.06 (± 14.6) months, 14 (40%) out of 35 fixed stems demonstrated stress shielding. Our results showed that the rate of stress shielding was significantly higher in cases with a bilateral ligament injury and in the anatomical press-fit group (p = 0.028 and p = 0.0091, respectively). However, stress shielding around prostheses did not affect the clinical results (p > 0.05).
conclusionThe stress shielding phenomenon around radial head prosthesis may vary according to prosthetic design and severity of ligament injuries. Stress shielding does not affect the mid-term outcomes in the treatment of acute fractures of the radial head. LEVEL OF EVIDENCE III: Retrospective Cohort Comparison; Treatment Study.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.