Evidence map›Paper›PMID 35762071›Full record

ArticleCardiology journal2022

First clinical experience of high-power ablation of atrial fibrillation with a novel contact force-sensing gold-tip catheter.

Abdul Shokor Parwani, Adrian Jayanata, Robin Kraft, Philipp Lacour, Florian Blaschke, Burkert Pieske, Leift-Hendrik Boldt

Open access · goldAbstract read
In one paragraph

Article in Cardiology journal, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 86% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Abdul Shokor ParwaniDepartment of Internal Medicine and Cardiology, Charité-Universitätsmedizin Berlin, Campus Virchow Klinikum, Berlin, Germany. abdul.parwani@charite.de.
Adrian JayanataDepartment of Internal Medicine and Cardiology, Charité-Universitätsmedizin Berlin, Campus Virchow Klinikum, Berlin, Germany.
Robin KraftDepartment of Internal Medicine and Cardiology, Charité-Universitätsmedizin Berlin, Campus Virchow Klinikum, Berlin, Germany.
Philipp LacourDepartment of Internal Medicine and Cardiology, Charité-Universitätsmedizin Berlin, Campus Virchow Klinikum, Berlin, Germany.
Florian BlaschkeDepartment of Internal Medicine and Cardiology, Charité-Universitätsmedizin Berlin, Campus Virchow Klinikum, Berlin, Germany.
Burkert PieskeDepartment of Internal Medicine and Cardiology, Charité-Universitätsmedizin Berlin, Campus Virchow Klinikum, Berlin, Germany.
Leift-Hendrik BoldtDepartment of Internal Medicine and Cardiology, Charité-Universitätsmedizin Berlin, Campus Virchow Klinikum, Berlin, Germany.
Charité - Universitätsmedizin Berlin · DEGerman Centre for Cardiovascular Research · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundContact force (CF)-sensing catheters are commonly used in the field of radiofrequency (RF) ablation to treat atrial fibrillation (AF). Increasing ablation power (e.g., 50 W) has been suggested as a method to reduce procedure times whilst creating safe and lasting lesions.

methodsWe report the first clinical evidence of a 50 W point-by-point RF ablation in 25 consecutive patients with symptomatic AF using a novel CF-sensing catheter with a gold tip (AlCath Force, Biotronik). We collected and analyzed procedural and ablation parameters. The safety and efficacy of the catheter were evaluated.

resultsAltogether, 985 RF lesions in 25 patients were created with a mean number of 39.4 ± 16.3 lesions per patient. The total skin-to-skin procedure time was 116.1 ± 35.1 min, and the mean total area dose product was 10.9 ± 5.1 Gy*cm2. The mean RF time per procedure was 13.2 ± 6.6 min. The mean RF time per lesion was 20.2 ± 8.4 s. The mean CF was 15.7 ± 7.6 g. We observed a mean force time integral of 274.7 ± 11.1 gs (range: 53 to 496 gs). Acute procedural success, defined as entrance and exit block in all pulmonary veins, could be obtained in all cases. No procedure- or device-related serious adverse events were observed. No audible steam pops occurred. Optical inspection of the catheter after the procedure showed neither charring nor clotting.

conclusionsWe provide the first evidence for the safety and efficacy of 50 W ablation using the AlCath Force gold-tip catheter. These data must be supported by a larger multi-center study.

Indexed as

Atrial FibrillationCatheter AblationPulmonary VeinsCathetersEquipment DesignGoldHumansSteamTreatment OutcomeGoldSteamablationatrial fibrillationcontact force sensinggold-tip catheterhigh power

Identifiers

PMID35762071
PMCPMC9550336
OpenAlexW4283646791

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked