Evidence map›Paper›PMID 35761323›Full record

ArticleBiomedical engineering online2022

In vivo experimental validation of detection of gastric slow waves using a flexible multichannel electrogastrography sensor linear array.

Atchariya Sukasem, Stefan Calder, Timothy R Angeli-Gordon, Christopher N Andrews, Gregory O'Grady, Armen Gharibans, Peng Du

Open access · goldAbstract read
In one paragraph

Article in Biomedical engineering online, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed, 1 pooled it
1.1field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 1 synthesis or guideline pooled it, 9 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 2 countries.

Atchariya SukasemUniversity of Auckland, Auckland, New Zealand.
Stefan CalderUniversity of Auckland, Auckland, New Zealand.
Timothy R Angeli-GordonUniversity of Auckland, Auckland, New Zealand.
Christopher N AndrewsUniversity of Auckland, Auckland, New Zealand.
Gregory O'GradyUniversity of Auckland, Auckland, New Zealand.
Armen GharibansUniversity of Auckland, Auckland, New Zealand.
Peng DuUniversity of Auckland, Auckland, New Zealand. peng.du@auckland.ac.nz.
University of Auckland · NZUniversity of Calgary · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundCutaneous electrogastrography (EGG) is a non-invasive technique that detects gastric bioelectrical slow waves, which in part govern the motility of the stomach. Changes in gastric slow waves have been associated with a number of functional gastric disorders, but to date accurate detection from the body-surface has been limited due to the low signal-to-noise ratio. The main aim of this study was to develop a flexible active-electrode EGG array.

methodsTwo Texas Instruments CMOS operational amplifiers: OPA2325 and TLC272BID, were benchtop tested and embedded in a flexible linear array of EGG electrodes, which contained four recording electrodes at 20-mm intervals. The cutaneous EGG arrays were validated in ten weaner pigs using simultaneous body-surface and serosal recordings, using the Cyton biosensing board and ActiveTwo acquisition systems. The serosal recordings were taken using a passive electrode array via surgical access to the stomach. Signals were filtered and compared in terms of frequency, amplitude, and phase-shift based on the classification of propagation direction from the serosal recordings.

resultsThe data were compared over 709 cycles of slow waves, with both active cutaneous EGG arrays demonstrating comparable performance. There was an agreement between frequencies of the cutaneous EGG and serosal recordings (3.01 ± 0.03 vs 3.03 ± 0.05 cycles per minute; p = 0.75). The cutaneous EGG also demonstrated a reduction in amplitude during abnormal propagation of gastric slow waves (310 ± 50 µV vs 277 ± 9 µV; p < 0.01), while no change in phase-shift was observed (1.28 ± 0.09 s vs 1.40 ± 0.10 s; p = 0.36).

conclusionA sparse linear cutaneous EGG array was capable of reliably detecting abnormalities of gastric slow waves. For more accurate characterization of gastric slow waves, a two-dimensional body-surface array will be required.

Indexed as

Gastrointestinal MotilityStomachAnimalsElectrodesElectromyographySignal-To-Noise RatioSwineEGGElectrophysiologyGastric slow wavesHigh-resolution mapping

Identifiers

PMID35761323
PMCPMC9238032
OpenAlexW4283579991

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.