Evidence map›Paper›PMID 35757282›Full record

ArticleProceedings of SPIE--the International Society for Optical Engineering

Potential use of microbubbles (MBs) as contrast material in x-ray dark field (DF) imaging: How does the DF signal change with the characteristic parameters of the MBs?

Ran Zhang, Bin Qin, Yongshuai Ge, Bruce Whiting, Ke Li, Flordeliza Villanueva, Guang-Hong Chen

Abstract read
In one paragraph

Article in Proceedings of SPIE--the International Society for Optical Engineering. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Ran ZhangDepartment of Medical Physics, University of Wisconsin School of Medicine and Public Health, Madison, WI.
Bin QinDepartment of Medicine, University of Pittsburgh, PA.
Yongshuai GeDepartment of Medical Physics, University of Wisconsin School of Medicine and Public Health, Madison, WI.
Bruce WhitingDepartment of Radiology, University of Pittsburgh, PA.
Ke LiDepartment of Medical Physics, University of Wisconsin School of Medicine and Public Health, Madison, WI.
Flordeliza VillanuevaDepartment of Medicine, University of Pittsburgh, PA.
Guang-Hong ChenDepartment of Medical Physics, University of Wisconsin School of Medicine and Public Health, Madison, WI.

Funding

Multi-Contrast X-ray Breast ImagingR01EB020521 · NIBIB · UNIVERSITY OF WISCONSIN-MADISON · PI CHEN, GUANG-HONG, LI, KE · 2016 to 2020
$2.0M
NIBIB NIH HHS R01 EB020521
6 · The paper itself

Abstract

One of the most exciting aspects of the grating based x-ray differential phase contrast (DPC) acquisition method is the concurrent generation of the so-called dark field (DF) signal, along with the classical absorption signal and the novel DPC signal. The DF signal is associated with local distribution of small angle scatterers in an image object, while the absorption signal and DPC signal are often used to characterize the relatively uniform structure of the image object. Besides the endogenous image contrast, exogenous contrast media are often used in x-ray imaging to locally enhance the image signal. This paper proposes a potential contrast medium for DF signal enhancement: microbubbles (MBs). MBs have already been developed for clinical use in ultrasound imaging, and recent experimental studies have shown that MBs may also enhance the DF signal, although it remained unclear how the physical characteristics of the MBs quantitatively impact the DF signal. In this paper, a systematic study was performed to investigate the quantitative relationships between the DF signal and the following properties of MBs: size, concentration, shell thickness, size uniformity, and whether gold nanoparticles were attached. The experimental results demonstrated that, an increased MB size (about 4 microns) may generate a stronger DF signal for our DPC imaging system; additionally, a moderately increased shell thickness and the use of gold nanoparticles on the shell surface also resulted in further enhancement of the DF signal. These findings may provide critical information needed for using MBs as the contrast agent of x-ray DF imaging.

Indexed as

microbubble contrast agentTalbot interferometryX-ray dark field imaging

Identifiers

PMID35757282
PMCPMC9231821

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.