Evidence map›Paper›PMID 35755981›Full record

ArticleJournal of medical signals and sensors

Implementation and Validation of a Novel Noninvasive blood Pressure Measurement Algorithm Based on Oscillometric Method with Obtaining International Hypertension Standards.

Sahar Karimian, Mohammadreza Yazdchi, Reza Hajian

Abstract read
In one paragraph

Article in Journal of medical signals and sensors. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Sahar KarimianDepartment of Biomedical Engineering, University of Isfahan, Isfahan, Iran.
Mohammadreza YazdchiDepartment of Biomedical Engineering, Faculty of Engineering, University of Isfahan, Isfahan, Iran.
Reza HajianDepartment of Biomedical Engineering, Amirkabir University of Technology, Tehran, Iran.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: One of the most prevalent methods in noninvasive blood pressure (BP) measurement with cuff is oscillometric, which has two different types of deflation, including linear and step deflation. With this approach, in addition to designing a novel algorithm by the step deflation method, a sample of its module was constructed and validated during clinical tests in different hospitals. Method: In this study, by controlling the valve, the pressure would be deflated through optimized steps. By real-time processing on the obtained signal from the pressure sensor, pulses in each step would be extracted. After that, in offline mode, mean arterial pressure is estimated based on curve fitting. Result: A BP simulator, various modules, and an auditory method were used to validate the algorithm and its results. During clinical tests, 80 people (men and women), 11 dialysis patients, and 69 non-dialysis (healthy or with other diseases) in the age range of 17-85 years participated. Conclusion: The obtained results compared with the BP simulator are in the standard range according to the international medical standards of the British Hypertension Society (BHS) and the US Association for the Advancement of Medical Instrumentation (AAMI), which are the global standard of comparison in this field.

Indexed as

Blood pressurecuffnoninvasive measurementoscillometric

Identifiers

PMID35755981
PMCPMC9215828

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.