Evidence map›Paper›PMID 35755977›Full record

ArticleJournal of medical signals and sensors

The Design of an Audit Test for

Mohammad Javad Tahmasebi Birgani, Hadis Khorshidsavar, Ali Bagheri, Amir Danyaei, Neda Abdalvand

Abstract read
In one paragraph

Article in Journal of medical signals and sensors. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Mohammad Javad Tahmasebi BirganiDepartment of Medical Physics, Medicine School, Ahvaz, Iran.
Hadis KhorshidsavarDepartment of Medical Physics, Medicine School, Ahvaz, Iran.
Ali BagheriDepartment of Radiation Oncology, Golestan Hospital, Ahvaz Jundishapur University of Medical Science, Ahvaz, Iran.
Amir DanyaeiDepartment of Medical Physics, Medicine School, Ahvaz, Iran.
Neda AbdalvandDepartment of Radiation Oncology, Golestan Hospital, Ahvaz Jundishapur University of Medical Science, Ahvaz, Iran.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Auditing the treatment planning system (TPS) software for a radiotherapy unit is of paramount importance in any radiation therapy department. A Plexiglas phantom was proposed to measure the ionization of Methods: Auditing was performed using a Plexiglas phantom in an end-to-end test, and relative dose points were detected by a farmer-type ionization chamber and compared with the relative dose of similar points in TPS. The audit results were determined as pass optimal level (<3.3%), pass action level (between 3.3% and 5%), and out of tolerance (>5%). Results: The comparison of the collected data revealed that 80% of the measured values were ≤5% in the pass level, and 20% of the points were out of tolerance (between 5% and 6.99%). Conclusion: This study documented the appropriateness of the dosimetry audit test and this phantom design for the HDR brachytherapy TPS.

Indexed as

AuditbrachytherapydosimetryPlexiglas phantomradiotherapy

Identifiers

PMID35755977
PMCPMC9215833

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.