Accelerating and improving radiochromic film calibration by utilizing the dose ratio in photon and proton beams.

Andreas F Resch, Fatima Padilla Cabal, Milovan Regodic, Wolfgang Lechner, Gerd Heilemann, Peter Kuess, Dietmar Georg, Hugo Palmans

Open access · hybridAbstract read
In one paragraph

Article in Medical physics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.3field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 5 citations in OpenAlex.

  1. Physical wedge as a tool for radiochromic film calibration.Zeitschrift fur medizinische Physik · 2025
    Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 2 countries.

Andreas F ReschDivision Medical Radiation Physics, Department of Radiation Oncology, Medical University of Vienna/AKH Wien, Vienna, Austria.
Fatima Padilla CabalDivision Medical Radiation Physics, Department of Radiation Oncology, Medical University of Vienna/AKH Wien, Vienna, Austria.
Milovan RegodicDivision Medical Radiation Physics, Department of Radiation Oncology, Medical University of Vienna/AKH Wien, Vienna, Austria.
Wolfgang LechnerDivision Medical Radiation Physics, Department of Radiation Oncology, Medical University of Vienna/AKH Wien, Vienna, Austria.
Gerd HeilemannDivision Medical Radiation Physics, Department of Radiation Oncology, Medical University of Vienna/AKH Wien, Vienna, Austria.
Peter KuessDivision Medical Radiation Physics, Department of Radiation Oncology, Medical University of Vienna/AKH Wien, Vienna, Austria.
Dietmar GeorgDivision Medical Radiation Physics, Department of Radiation Oncology, Medical University of Vienna/AKH Wien, Vienna, Austria.
Hugo PalmansMedAustron Ion Therapy Centre, Wiener Neustadt, Austria.
Medical University of Vienna · ATMedAustron · AT

Funding

Österreichische Forschungsförderungsgesellschaft (FFG) 874709
6 · The paper itself

Abstract

purposeRadiochromic films are versatile 2D dosimeters with high-resolution and near tissue equivalence. To assure high precision and accuracy, a time-consuming calibration process is required. To improve the time efficiency, a novel calibration method utilizing the ratio of the same dose profile measured at different monitor units (MUs) is introduced and tested in a proton and photon beam.

methodsThe calibration procedure employs the dose ratio of film measurements of the same relative profile for different absolute dose values. Hence, the ratio of the dose is constant at any point of the profile, but the ratio of the net optical densities is not constant. The key idea of the method is to optimize the calibration function until the ratio of the calculated doses is constant. The proposed method was tested in the dose range between 0.25-12 and 1-6 Gy in a proton and photon beam, respectively. A radial symmetric profile and a rectangular profile were created, both having a central plateau region of about 3 cm diameter and a dose falloff of about 1.5 cm at larger distances. The dose falloff region was used as input for the optimization method and the central plateau region served as dose reference points. Only the plateau region of the highest dose entered the optimization as an additional objective. The measured data were randomly split into differently sized training and test sets. The optimization was repeated 1000 times with random start value initialization using the same start values for the standard and the gradient method. Finally, a proton plan with four dose levels was created, which were separated spatially, to test the possibility of a full calibration within a single measurement.

resultsParameter estimation was possible with as low as one dose ratio used for optimization in both the photon and the proton case, yet exhibiting a high sensitivity on the dose level. The root mean squared deviation (RMSD) of the dose was less than 1% when the dose ratio was in the order of 20, whereas the median RMSD of all optimizations was 1.7%. Using four dose levels for optimization resulted in a median RMSD of 1% when randomly selecting the dose levels. Having at least one dose ratio of about 20 included in the optimization considerably improved the RMSD of the calibration function. Using six or eight dose levels reduced the sensitivity on the dose level selection and the median RMSD was 0.8%. A full calibration was possible in a single measurement having four dose levels in one plan but spatially separated.

conclusionsThe number of measurements required to obtain an EBT3 film calibration function could be reduced using the proposed dose ratio method while maintaining the same accuracy as with the standard method.

Indexed as

Film DosimetryProton TherapyCalibrationPhotonsProtonsProtonsdose calibrationGafchromic EBT3radiochromic film

Identifiers

PMID35754376
PMCPMC9543697
OpenAlexW4283580333

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.