ArticleScientific reports2022
Performance improvement and thermodynamic assessment of microchannel heat sink with different types of ribs and cones.
Article in Scientific reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 19 citations in OpenAlex.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 4 institutions in 4 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The present study aims to investigate the performance of microchannel heat sink via numerical simulations, based on the first and second law of thermodynamics. The heat transfer and flow characteristics of rectangular microchannel heat sinks have been improved by adding six different types of surface enhancers. The cross-sections include rectangular, triangular, and hexagonal-shaped ribs and cones. The cones have been created from the same cross-sections of ribs by drafting them at an angle of 45° orthogonal to the base, which is expected to decrease the pressure drop, dramatically. The performance of ribs and cones has been evaluated using different parameters such as friction factor, wall shear stress, entropy generation rate, augmentation entropy generation number, thermal resistance, and transport efficiency of thermal energy. The results of the present study revealed that the novel effect of coning at an angle of 45° reduces frictional losses (Maximum pressure drop reduced is 85%), however; a compromise on thermal behavior has been shown (Maximum Nusselt number reduced is 25%). Similarly, the application of coning has caused a significant reduction in wall shear stress and friction factor which can lead to reducing the pumping power requirements. Moreover, triangular ribs have more ability to transfer thermal energy than rectangular and hexagonal ribs. Furthermore, it has been examined in the present study that the trend of total entropy generation rate for triangular ribs decreases up to Re = 400 and then increases onwards which means that thermal losses are more significant than frictional losses at lower Reynolds number. However, frictional losses dominate over thermal losses at higher Reynolds numbers, where vortex generation takes place, especially in triangular ribs.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.