Evidence map›Paper›PMID 35749428›Full record

ArticlePloS one2022

Diagnostic sensitivity and cost per diagnosis of ambulatory cardiac monitoring strategies in unexplained syncope patients.

John D Rogers, Lucas Higuera, Sarah C Rosemas, Ya-Jian Cheng, Paul D Ziegler

Abstract read
In one paragraph

Article in PloS one, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Trial
  2. Review
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

John D RogersScripps Clinic, Cardiac Pacing and Tachyarrhythmia Device Therapy, La Jolla, CA, United States of America.
Lucas HigueraMedtronic Inc, Cardiac Rhythm & Heart Failure, Mounds View, MN, United States of America.ORCID 0000-0002-1443-6740
Sarah C RosemasMedtronic Inc, Cardiac Rhythm & Heart Failure, Mounds View, MN, United States of America.
Ya-Jian ChengMedtronic Inc, Cardiac Rhythm & Heart Failure, Mounds View, MN, United States of America.
Paul D ZieglerMedtronic Inc, Cardiac Rhythm & Heart Failure, Mounds View, MN, United States of America.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Diagnosing cardiac pauses that could produce syncopal episodes is important to guide appropriate therapy. However, the infrequent nature of these episodes can make detection challenging with conventional monitoring (CM) strategies with short-term ECG monitors. Insertable cardiac monitors (ICMs) continuously monitor for arrhythmias but present a higher up-front cost. It is not well understood whether these higher costs are offset by the costs of repeat evaluation in CM strategies. We simulated the likelihood of diagnostic success and cost-per-diagnosis of pause arrhythmias with CM strategies compared to ICM monitoring. ICM device data from syncope patients diagnosed with pause arrhythmias was utilized to simulate patient pathways and diagnostic success with CM. We assumed that detected true pause episodes (≥5 seconds) were symptomatic and prompted a hospital encounter and further evaluation with CM. Subsequent true pause episodes in yet-undiagnosed patients triggered additional rounds of CM. Costs of monitoring were accrued at each encounter and represent the U.S. payer perspective. Cost per diagnosed patient was calculated as the total costs accrued for all patients divided by the number of patients diagnosed, across 1,000 simulations. During a mean 505±333 days of monitoring ICM detected 2.4±2.7 pause events per patient, with an average of 109±94 days until the first event. CM was projected to diagnose between 13.8% (24-hour Holter) and 30.2% (two 30-day monitors) of the ICM-diagnosed patients. Total diagnostic costs per ICM-diagnosed patient averaged $7,847, whereas in the CM strategies average cost-per-diagnosis ranged from $12,950±2,589 with 24-hour Holter to $32,977±14,749 for two 30-day monitors. Relative to patients diagnosed with pause arrhythmias via ICM, CM strategies diagnose fewer patients and incur higher costs per diagnosed patient.

Indexed as

Atrial FibrillationElectrocardiography, AmbulatoryElectrocardiographyHumansSyncope

Identifiers

PMID35749428
PMCPMC9231770

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.