Evidence map›Paper›PMID 35746324›Full record

ArticleSensors (Basel, Switzerland)2022

Efficient Illumination for a Light-Addressable Potentiometric Sensor.

Tatsuo Yoshinobu, Ko-Ichiro Miyamoto

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Tatsuo YoshinobuDepartment of Biomedical Engineering, Tohoku University, Sendai 980-8579, Japan.ORCID 0000-0001-7993-716X
Ko-Ichiro MiyamotoDepartment of Electronic Engineering, Tohoku University, Sendai 980-8579, Japan.

Funding

Japan Society for the Promotion of Science 22H02100
6 · The paper itself

Abstract

A light-addressable potentiometric sensor (LAPS) is a chemical sensor that is based on the field effect in an electrolyte-insulator-semiconductor structure. It requires modulated illumination for generating an AC photocurrent signal that responds to the activity of target ions on the sensor surface. Although high-power illumination generates a large signal, which is advantageous in terms of the signal-to-noise ratio, excess light power can also be harmful to the sample and the measurement. In this study, we tested different waveforms of modulated illuminations to find an efficient illumination for a LAPS that can enlarge the signal as much as possible for the same input light power. The results showed that a square wave with a low duty ratio was more efficient than a sine wave by a factor of about two.

Indexed as

Biosensing TechniquesLightingLightPotentiometrySemiconductorsduty ratiofield-effect deviceLAPSlight-addressable potentiometric sensorlock-in detectionmodulated illuminationphotocurrentpH sensorsquare wavewaveform

Identifiers

PMID35746324
PMCPMC9227191

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.