Evidence map›Paper›PMID 35745901›Full record

ArticlePolymers2022

Batch Fabrication of a Polydimethylsiloxane Based Stretchable Capacitive Strain Gauge Sensor for Orthopedics.

Karthika Sheeja Prakash, Hermann Otto Mayr, Prachi Agrawal, Priyank Agarwal, Michael Seidenstuecker, Nikolaus Rosenstiel, Peter Woias, Laura Maria Comella

Open access · goldAbstract read
In one paragraph

Article in Polymers, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.8field-weighted citation impact, top 33% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 11 citations in OpenAlex.

  1. Article
  2. Digital measurement of anterolateral knee laxity using strain sensors.Archives of orthopaedic and trauma surgery · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Karthika Sheeja PrakashDepartment of Microsystems Engineering-IMTEK, University of Freiburg, 79110 Freiburg im Breisgau, Germany.
Hermann Otto MayrDepartment of Orthopedics and Trauma Surgery, The University Medical Center Freiburg, 79106 Freiburg im Breisgau, Germany.ORCID 0000-0002-5100-0372
Prachi AgrawalDepartment of Microsystems Engineering-IMTEK, University of Freiburg, 79110 Freiburg im Breisgau, Germany.
Priyank AgarwalDepartment of Microsystems Engineering-IMTEK, University of Freiburg, 79110 Freiburg im Breisgau, Germany.
Michael SeidenstueckerGewebeersatz, Regeneration & Neogenese (G.E.R.N.), Department of Orthopedics and Trauma Surgery, The University Medical Centre Freiburg, 79108 Freiburg im Breisgau, Germany.ORCID 0000-0001-6643-6358
Nikolaus RosenstielDepartment of Orthopedics and Trauma Surgery, The University Medical Center Freiburg, 79106 Freiburg im Breisgau, Germany.
Peter WoiasDepartment of Microsystems Engineering-IMTEK, University of Freiburg, 79110 Freiburg im Breisgau, Germany.
Laura Maria ComellaDepartment of Microsystems Engineering-IMTEK, University of Freiburg, 79110 Freiburg im Breisgau, Germany.
University of Freiburg · DEUniversity Medical Center Freiburg · DE

Funding

Deutsche Forschungsgemeinschaft WO 883/16-3
6 · The paper itself

Abstract

Polymer-based capacitive strain gauges are a novel and promising concept for measuring large displacements and strains in various applications. These novel sensors allow for high strain, well above the maximum values achieved with state-of-the-art strain gauges (Typ. 1%). In recent years, a lot of interest in this technology has existed in orthopedics, where the sensors have been used to measure knee laxity caused by a tear of the anterior cruciate ligament (ACL), and for other ligament injuries. The validation of this technology in the field has a very low level of maturity, as no fast, reproducible, and reliable manufacturing process which allows mass production of sensors with low cost exists. For this reason, in this paper, a new approach for the fabrication of polymer-based capacitive strain gauges is proposed, using polydimethylsiloxane (PDMS) as base material. It allows (1) the fast manufacturing of sensor batches with reproducible geometry, (2) includes a fabrication step for embedding rigid electrical contacts on the sensors, and (3) is designed to produce sensor batches in which the size, the number, and the position of the sensors can be adapted to the patient's anatomy. In the paper, the process repeatability and the robustness of the design are successfully proven. After 1000 large-strain elongation cycles, in the form of accelerated testing caused much higher strains than in the above-mentioned clinical scenario, the sensor's electrical contacts remained in place and the functionalities were unaltered. Moreover, the prototype of a patient customizable patch, embedding multiple sensors, was produced.

Indexed as

ACL rupturebatch fabricationCarbon black-PDMSelectronic contactingflexible sensor mold fabricationknee jointPDMS

Identifiers

PMID35745901
PMCPMC9228458
OpenAlexW4282582397

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.