Evidence map›Paper›PMID 35744343›Full record

ArticleMaterials (Basel, Switzerland)2022

Demonstration of Use of a Novel 3D Printed Simulator for Mitral Valve Transcatheter Edge-to-Edge Repair (TEER).

Michele Bertolini, Michael Mullen, Georgios Belitsis, Angel Babu, Giorgio Colombo, Andrew Cook, Aigerim Mullen, Claudio Capelli

Open access · goldAbstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
1.3field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it, 8 citations in OpenAlex.

  1. 3D Printing for Mitral Valve Disease: A Systematic Review.Interdisciplinary cardiovascular and thoracic surgery · 2026
    Pooled it
  2. Article
  3. Review
  4. Article
  5. Review
  6. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 2 countries.

Michele BertoliniDepartment of Mechanical Engineering, Politecnico di Milano, 20133 Milan, Italy.ORCID 0000-0001-5256-181X
Michael MullenBarts Health NHS Trust, London E1 1BB, UK.
Georgios BelitsisInstitute of Cardiovascular Science, University College London, London WC1E 6BT, UK.
Angel BabuInstitute of Cardiovascular Science, University College London, London WC1E 6BT, UK.
Giorgio ColomboDepartment of Mechanical Engineering, Politecnico di Milano, 20133 Milan, Italy.ORCID 0000-0002-9999-8960
Andrew CookInstitute of Cardiovascular Science, University College London, London WC1E 6BT, UK.
Aigerim MullenInstitute of Cardiovascular Science, University College London, London WC1E 6BT, UK.
Claudio CapelliInstitute of Cardiovascular Science, University College London, London WC1E 6BT, UK.
University College London · GBPolitecnico di Milano · ITBarts Health NHS Trust · GB

Funding

British Heart Foundation PG/16/99/32572
6 · The paper itself

Abstract

Mitral regurgitation is a common valvular disorder. Transcatheter edge-to-edge repair (TEER) is a minimally invasive technique which involves holding together the middle segments of the mitral valve leaflets, thereby reducing regurgitation. To date, MitraClip™ is the only Food and Drug Administration (FDA)-approved device for TEER. The MitraClip procedure is technically challenging, characterised by a steep learning curve. Training is generally performed on simplified models, which do not emphasise anatomical features, realistic materials, or procedural scenarios. The aim of this study is to propose a novel, 3D printed simulator, with a major focus on reproducing the anatomy and plasticity of all areas of the heart involved and specifically the ones of the mitral valve apparatus. A three-dimensional digital model of a heart was generated by segmenting computed tomography (CT). The model was subsequently modified for: (i) adding anatomical features not fully visible with CT; (ii) adapting the model to interact with the MitraClip procedural equipment; and (iii) ensuring modularity of the system. The model was manufactured with a Polyjet technology printer, with a differentiated material assignment among its portions. Polypropylene threads were stitched to replicate chordae tendineae. The proposed system was successfully tested with MitraClip equipment. The simulator was assessed to be feasible to practice in a realistic fashion, different procedural aspects including access, navigation, catheter steering, and leaflets grasping. In addition, the model was found to be compatible with clinical procedural imaging fluoroscopy equipment. Future studies will assess the effect of the proposed training system on improving TEER training.

Indexed as

3D printingMitraClip proceduremitral valve regurgitationPolyjetsegmentationsimulation-based trainingtranscatheter edge-to-edge repair

Identifiers

PMID35744343
PMCPMC9227763
OpenAlexW4283009985

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked