ArticleMedicina (Kaunas, Lithuania)2022
Deviating from the Recommended Torque on Set Screws Can Reduce the Stability and Fatigue Life of Pedicle Screw Fixation Devices.
Article in Medicina (Kaunas, Lithuania), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed, 5 citations in OpenAlex.
- Distal instrumentation failure after posterior spinal fusion in adolescent idiopathic scoliosis: Incidence, risk factors, and radiographic consequences.Spine deformity · 2026Article
- Biomechanical evaluation of a novel cervical interfacet self-locking cage versus ACDF: a goat cadaveric study combined with human CT-based finite element analysis.BMC musculoskeletal disorders · 2026Article
- The influence of the interfacing angle between the pedicle screw and support rods on the clinical outcomes after posterior lumbar-sacral topping-off surgery: A retrospective clinical study.Journal of orthopaedic surgery and research · 2025Observational
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background and Objectives: Using an appropriate torque to tighten set screws ensures the long-term stability of spinal posterior fixation devices. However, the recommended torque often varies between different devices and some devices do not state a recommended torque level. The purpose of this study is to evaluate the effect of set screw torque on the overall construct stability and fatigue life. Materials and Methods: Two commercial pedicle screw systems with different designs for the contact interface between the set screw and rod (Group A: plane contact, Group B: line contact) were assembled using torque wrenches provided with the devices to insert the set screws and tighten to the device specifications. The axial gipping capacity and dynamic mechanical stability of each bilateral construct were assessed in accordance with ASTM F1798 and ASTM F1717. Results: Increasing or decreasing the torque on the set screw by 1 Nm from the recommended level did not have a significant effect on the axial gripping capacity or fatigue strength of Group A (p > 0.05). For Group B, over-tightening the set screw by 1 Nm did cause a significant reduction in the fatigue strength. Conclusions: Excessive torque can damage the rod surface and cause premature failure. When insertion using a manual driver is preferred, a plane contact interface between the set screw and rod can reduce damage to the rod surface when the set screw is over-torqued.
Indexed as
Identifiers
What OpenQuestion holds