Evidence map›Paper›PMID 35743696›Full record

ArticleJournal of personalized medicine2022

In Vivo Verification of Treatment Source Dwell Times in Brachytherapy of Postoperative Endometrial Carcinoma: A Feasibility Study.

Antonio Herreros, José Pérez-Calatayud, Facundo Ballester, Jose Barrera-Gómez, Rosa Abellana, Joana Melo, Luis Moutinho, Luca Tagliaferri, Ángeles Rovirosa

Open access · goldAbstract read
In one paragraph

Article in Journal of personalized medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.8field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. The clinical application of in vivo dosimetry for gynaecological brachytherapy: A scoping review.Technical innovations & patient support in radiation oncology · 2025
    Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 6 institutions in 2 countries.

Antonio HerrerosFonaments Clínics Department, University of Barcelona, 08036 Barcelona, Spain.
José Pérez-CalatayudRadiation Oncology Department, Hospital Universitari i Politècnic La Fe, 46026 Valencia, Spain.
Facundo BallesterIRIMED, IIS-La Fe-Universitat de Valencia (UV), 46100 Burjassot, Spain.ORCID 0000-0002-3785-8399
Jose Barrera-GómezMathematics Department, Autonomous University of Barcelona, 08193 Bellatera, Spain.ORCID 0000-0002-2688-6036
Rosa AbellanaFonaments Clínics Department, University of Barcelona, 08036 Barcelona, Spain.
Joana MeloNU-RISE LDA, PCI-Creative Science Park, 3830-352 Ilhavo, Portugal.
Luis MoutinhoNU-RISE LDA, PCI-Creative Science Park, 3830-352 Ilhavo, Portugal.
Luca TagliaferriU.O.C. Radioterapia Oncologica, Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, Fondazione Policlinico Universitario A. Gemelli IRCCS, 00168 Rome, Italy.ORCID 0000-0003-2308-0982
Ángeles RovirosaFonaments Clínics Department, University of Barcelona, 08036 Barcelona, Spain.ORCID 0000-0002-7832-334X
Hospital Universitari de Vic · ESAgostino Gemelli University Polyclinic · ITHospital Universitari i Politècnic La Fe · ESUniversitat Autònoma de Barcelona · ESUniversitat de Barcelona · ESUniversitat de València · ES

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

(1) Background: In brachytherapy, there are still many manual procedures that can cause adverse events which can be detected with in vivo dosimetry systems. Plastic scintillator dosimeters (PSD) have interesting properties to achieve this objective such as real-time reading, linearity, repeatability, and small size to fit inside brachytherapy catheters. The purpose of this study was to evaluate the performance of a PSD in postoperative endometrial brachytherapy in terms of source dwell time accuracy. (2) Methods: Measurements were carried out in a PMMA phantom to characterise the PSD. Patient measurements in 121 dwell positions were analysed to obtain the differences between planned and measured dwell times. (3) Results: The repeatability test showed a relative standard deviation below 1% for the measured dwell times. The relative standard deviation of the PSD sensitivity with accumulated absorbed dose was lower than 1.2%. The equipment operated linearly in total counts with respect to absorbed dose and also in count rate versus absorbed dose rate. The mean (standard deviation) of the absolute differences between planned and measured dwell times in patient treatments was 0.0 (0.2) seconds. (4) Conclusions: The PSD system is useful as a quality assurance tool for brachytherapy treatments.

Indexed as

brachytherapyendometrial carcinomain vivo dosimetryplastic scintillator dosimetertreatment verification

Identifiers

PMID35743696
PMCPMC9224704
OpenAlexW4281820079