Evidence map›Paper›PMID 35741195›Full record

ArticleDiagnostics (Basel, Switzerland)2022

Reliability of Gradient-Echo Magnetic Resonance Elastography of Lumbar Muscles: Phantom and Clinical Studies.

Tsyh-Jyi Hsieh, Ming-Chung Chou, Yi-Chu Chen, Yi-Chen Chou, Chien-Hung Lin, Clement Kuen-Huang Chen

Open access · goldAbstract read
In one paragraph

Article in Diagnostics (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.7field-weighted citation impact, top 32% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Tsyh-Jyi HsiehDepartment of Medical Imaging, Chi Mei Medical Center, Yongkang, Tainan 71004, Taiwan.ORCID 0000-0001-9076-6584
Ming-Chung ChouDepartment of Medical Imaging and Radiological Sciences, Kaohsiung Medical University, Kaohsiung 80708, Taiwan.ORCID 0000-0001-8488-2693
Yi-Chu ChenDepartment of Medical Imaging and Radiological Sciences, Kaohsiung Medical University, Kaohsiung 80708, Taiwan.ORCID 0000-0002-5912-3860
Yi-Chen ChouDepartment of Medical Imaging, Chi Mei Medical Center, Yongkang, Tainan 71004, Taiwan.
Chien-Hung LinDepartment of Medical Imaging, Chi Mei Medical Center, Yongkang, Tainan 71004, Taiwan.
Clement Kuen-Huang ChenDepartment of Medical Imaging, Chi Mei Medical Center, Yongkang, Tainan 71004, Taiwan.
Chi Mei Medical Center · TWKaohsiung Medical University · TW

Funding

Chi Mei Medical Center CMFHR10972
6 · The paper itself

Abstract

Magnetic resonance elastography (MRE) has been used to successfully characterize the mechanical behavior of healthy and diseased muscles, but no study has been performed to investigate the reliability of MRE on lumbar muscles. The objective of this work was to determine the reliability of MRE techniques on lumbar muscles in both ex vivo phantom and in vivo human studies. In this study, fresh porcine leg muscles were used in the phantom study, and 80 healthy adults (38.6 ± 11.2 years, 40 women) were recruited in the human study. Five repeated stiffness maps were obtained from both the phantom and human muscles by using a gradient-echo MRE sequence with a pneumatic vibration on a 1.5 T MR scanner. The technical failure rate, coefficient of variation (CV), and quality score were assessed to evaluate the reliability of MRE, respectively. Analysis of variance was performed to compare the stiffness between different lumbar muscles, and the difference was significant if p < 0.05 after Bonferroni correction. The results showed that the MRE achieved a zero technical failure rate and a low CV of stiffness (6.24 ± 1.41%) in the phantom muscles. However, in the human study, the MRE exhibited high CVs of stiffness (21.57%−25.24%) in the lumbar muscles, and the technical failure rate was higher in psoas muscles (60.0−66.3% in) than in paraspinal muscles (0.0−2.5%). Further, higher quality scores were noticed in paraspinal muscles (7.31−7.71) than those in psoas muscles (1.83−2.06). In conclusion, the MRE was a reliable technique to investigate the mechanical property of lumbar muscles, but it was less reliable to assess stiffness in psoas muscles than paraspinal muscles.

Indexed as

lumbar spineMR elastographymusclequality scorestiffnesstechnical failure rate

Identifiers

PMID35741195
PMCPMC9221855
OpenAlexW4281781178

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.