Evidence map›Paper›PMID 35741127›Full record

ArticleDiagnostics (Basel, Switzerland)2022

Concordance between SIVA, IVAN, and VAMPIRE Software Tools for Semi-Automated Analysis of Retinal Vessel Caliber.

Thibaud Mautuit, Pierre Cunnac, Carol Y Cheung, Tien Y Wong, Stephen Hogg, Emanuele Trucco, Vincent Daien, Thomas J MacGillivray, José Labarère, Christophe Chiquet

Abstract read
In one paragraph

Article in Diagnostics (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Thibaud MautuitHP2 Laboratory, INSERM U1300, Univ. Grenoble Alpes, 38700 La Tronche, France.ORCID 0000-0003-1236-930X
Pierre CunnacHP2 Laboratory, INSERM U1300, Univ. Grenoble Alpes, 38700 La Tronche, France.
Carol Y CheungDepartment of Ophthalmology and Visual Sciences, The Chinese University of Hong Kong, Hong Kong, China.
Tien Y WongSingapore Eye Research Institute, Yong Loo Ling School of Medicine, National University of Singapore, Singapore 119077, Singapore.
Stephen HoggVAMPIRE Project, School of Computing, University of Dundee, Dundee DD1 4HN, UK.
Emanuele TruccoVAMPIRE Project, School of Computing, University of Dundee, Dundee DD1 4HN, UK.
Vincent DaienDepartment of Ophthalmology, Gui De Chauliac Hospital, 34295 Montpellier, France.
Thomas J MacGillivrayVAMPIRE Project, Clinical Research Imaging Centre, University of Edinburgh, Edinburgh EH8 9YL, UK.
José LabarèreClinical Epidemiology Unit, Grenoble University Hospital, 38043 Grenoble, France.ORCID 0000-0001-7621-6586
Christophe ChiquetHP2 Laboratory, INSERM U1300, Univ. Grenoble Alpes, 38700 La Tronche, France.ORCID 0000-0002-7601-4885

Funding

ARFO ARFO_2019 ivan siva vampire
6 · The paper itself

Abstract

We aimed to compare measurements from three of the most widely used software packages in the literature and to generate conversion algorithms for measurement of the central retinal artery equivalent (CRAE) and central retinal vein equivalent (CRVE) between SIVA and IVAN and between SIVA and VAMPIRE. We analyzed 223 retinal photographs from 133 human participants using both SIVA, VAMPIRE and IVAN independently for computing CRAE and CRVE. Agreement between measurements was assessed using Bland-Altman plots and intra-class correlation coefficients. A conversion algorithm between measurements was carried out using linear regression, and validated using bootstrapping and root-mean-square error. The agreement between VAMPIRE and IVAN was poor to moderate: The mean difference was 20.2 µm (95% limits of agreement, LOA, -12.2-52.6 µm) for CRAE and 21.0 µm (95% LOA, -17.5-59.5 µm) for CRVE. The agreement between VAMPIRE and SIVA was also poor to moderate: the mean difference was 36.6 µm (95% LOA, -12.8-60.4 µm) for CRAE, and 40.3 µm (95% LOA, 5.6-75.0 µm) for CRVE. The agreement between IVAN and SIVA was good to excellent: the mean difference was 16.4 µm (95% LOA, -4.25-37.0 µm) for CRAE, and 19.3 µm (95% LOA, 0.09-38.6 µm) for CRVE. We propose an algorithm converting IVAN and VAMPIRE measurements into SIVA-estimated measurements, which could be used to homogenize sets of vessel measurements obtained with different software packages.

Indexed as

central retinal artery equivalentcentral retinal vein equivalentconversion algorithmIVAN softwareretinal vessel measurementsSIVA softwareVAMPIRE software

Identifiers

PMID35741127
PMCPMC9221842

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.