Evidence map›Paper›PMID 35740615›Full record

ArticleCancers2022

The Early Detection of Breast Cancer Using Liquid Biopsies: Model Estimates of the Benefits, Harms, and Costs.

Esmée K J van der Poort, Nicolien T van Ravesteyn, Jeroen J van den Broek, Harry J de Koning

Abstract read
In one paragraph

Article in Cancers, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Review
  4. Review
  5. Review
  6. Review
  7. Review
  8. Review
  9. Article
  10. Review
  11. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Esmée K J van der PoortDepartment of Public Health, Erasmus Medical Center, 3015 GD Rotterdam, The Netherlands.ORCID 0000-0001-5364-2558
Nicolien T van RavesteynDepartment of Public Health, Erasmus Medical Center, 3015 GD Rotterdam, The Netherlands.ORCID 0000-0003-3531-466X
Jeroen J van den BroekDepartment of Public Health, Erasmus Medical Center, 3015 GD Rotterdam, The Netherlands.
Harry J de KoningDepartment of Public Health, Erasmus Medical Center, 3015 GD Rotterdam, The Netherlands.ORCID 0000-0003-4682-3646

Funding

Comparative Modeling of Precision Breast Cancer Control Across the Translational Continuum - SupplementU01CA253911 · NCI · UNIVERSITY OF WISCONSIN-MADISON · PI ALAGOZ, OGUZHAN, DE KONING, HARRY J · 2020 to 2025
$10.6M
Comparative Modeling: Informing Breast Cancer Control Practice and PolicyU01CA199218 · NCI · GEORGETOWN UNIVERSITY · PI BERRY, DONALD A, DE KONING, HARRY J · 2015 to 2019
$9.0M
NCI NIH HHS U01 CA199218NCI NIH HHS U01 CA253911NIH HHS U01 CA199218
6 · The paper itself

Abstract

Breast cancer screening is associated with harms, such as false-positives and overdiagnoses, and, thus, novel screen tests can be considered. Liquid biopsies have been proposed as a novel method for the early detection of cancer, but low cell-free DNA tumor fraction might pose a problem for the use in population screening. Using breast cancer microsimulation model MISCAN-Fadia, we estimated the outcomes of using liquid biopsies in breast cancer screening in women aged 50 to 74 in the United States. For varying combinations of test sensitivity and specificity, we quantify the impact of the use of liquid biopsies on the harms and benefits of screening, and we estimate the maximum liquid biopsy price for cost-effective implementation in breast cancer screening at a cost-effectiveness threshold of USD 50,000. We investigate under what conditions liquid biopsies could be a suitable alternative to digital mammography and compare these conditions to a CCGA substudy. Outcomes were compared to digital mammography screening, and include mortality reduction, overdiagnoses, quality-adjusted life-years (QALYs), and the maximum price of a liquid biopsy for cost-effective implementation. When liquid biopsies are unable to detect DCIS, a large proportion of overdiagnosed cases is prevented but overall breast cancer mortality reduction and quality of life are lower, and costs are higher compared to digital mammography screening. Liquid biopsies prices should be restricted to USD 187 per liquid biopsy depending on test performance. Overall, liquid biopsies that are unable to detect ductal carcinoma in situ (DCIS) need to be able to detect small, early-stage tumors, with high specificity, at low costs in order to be an alternative to digital mammography. Liquid biopsies might be more suitable as an addition to digital mammography than as an alternative.

Indexed as

breast cancercirculating tumor DNAcost-effectivenessdigital mammographyductal carcinoma in situliquid biopsyoverdiagnosesscreening

Identifiers

PMID35740615
PMCPMC9220983

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.