Evidence map›Paper›PMID 35736881›Full record

ArticleTomography (Ann Arbor, Mich.)2022

Follow-Up Assessment of Intracranial Aneurysms Treated with Endovascular Coiling: Comparison of Compressed Sensing and Parallel Imaging Time-of-Flight Magnetic Resonance Angiography.

Gianfranco Vornetti, Fiorina Bartiromo, Francesco Toni, Massimo Dall'Olio, Mario Cirillo, Peter Speier, Ciro Princiotta, Michaela Schmidt, Caterina Tonon, Domenico Zacà and 2 more

Open access · goldAbstract read
In one paragraph

Article in Tomography (Ann Arbor, Mich.), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.1field-weighted citation impact, top 54% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors at 3 institutions in 2 countries.

Gianfranco VornettiIRCCS Istituto delle Scienze Neurologiche di Bologna, UOC di Neuroradiologia, 40139 Bologna, Italy.ORCID 0000-0001-6409-7962
Fiorina BartiromoIRCCS Istituto delle Scienze Neurologiche di Bologna, Programma Neuroimmagini Funzionali e Molecolari, 40139 Bologna, Italy.
Francesco ToniIRCCS Istituto delle Scienze Neurologiche di Bologna, Programma di Neuroradiologia con Tecniche ad Elevata Complessità, 40139 Bologna, Italy.
Massimo Dall'OlioIRCCS Istituto delle Scienze Neurologiche di Bologna, UOC di Neuroradiologia, 40139 Bologna, Italy.
Mario CirilloDipartimento di Scienze Mediche e Chirurgiche Avanzate, Università della Campania "Luigi Vanvitelli", 81100 Napoli, Italy.ORCID 0000-0001-5350-7700
Peter SpeierSiemens Healthineers, 91052 Erlangen, Germany.
Ciro PrinciottaIRCCS Istituto delle Scienze Neurologiche di Bologna, UOC di Neuroradiologia, 40139 Bologna, Italy.
Michaela SchmidtSiemens Healthineers, 91052 Erlangen, Germany.
Caterina TononIRCCS Istituto delle Scienze Neurologiche di Bologna, Programma Neuroimmagini Funzionali e Molecolari, 40139 Bologna, Italy.
Domenico ZacàSiemens Healthineers, 91052 Erlangen, Germany.
Raffaele LodiIRCCS Istituto delle Scienze Neurologiche di Bologna, Programma Neuroimmagini Funzionali e Molecolari, 40139 Bologna, Italy.
Luigi CirilloIRCCS Istituto delle Scienze Neurologiche di Bologna, UOC di Neuroradiologia, 40139 Bologna, Italy.
Istituto delle Scienze Neurologiche di Bologna · ITSiemens Healthineers (Germany) · DEUniversity of Campania "Luigi Vanvitelli" · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The aim of our study was to compare compressed sensing (CS) time-of-flight (TOF) magnetic resonance angiography (MRA) with parallel imaging (PI) TOF MRA in the evaluation of patients with intracranial aneurysms treated with coil embolization or stent-assisted coiling. We enrolled 22 patients who underwent follow-up imaging after intracranial aneurysm coil embolization. All patients underwent both PI TOF and CS TOF MRA during the same examination. Image evaluation aimed to compare the performance of CS to PI TOF MRA in determining the degree of aneurysm occlusion, as well as the depiction of parent vessel and vessels adjacent to the aneurysm dome. The reference standard for the evaluation of aneurysm occlusion was PI TOF MRA. The inter-modality agreement between CS and PI TOF MRA in the evaluation of aneurysm occlusion was almost perfect (κ  =  0.98, p  <  0.001) and the overall inter-rater agreement was substantial (κ  =  0.70, p  <  0.001). The visualization of aneurysm parent vessel in CS TOF images compared with PI TOF images was evaluated to be better in 11.4%, equal in 86.4%, and worse in 2.3%. CS TOF MRA, with almost 70% scan time reduction with respect to PI TOF MRA, yields comparable results for assessing the occlusion status of coiled intracranial aneurysms. Short scan times increase patient comfort, reduce the risk of motion artifacts, and increase patient throughput, with a resulting reduction in costs. CS TOF MRA may therefore be a potential replacement for PI TOF MRA as a first-line follow-up examination in patients with intracranial aneurysms treated with coil embolization.

Indexed as

Embolization, TherapeuticIntracranial AneurysmAngiography, Digital SubtractionFollow-Up StudiesHumansMagnetic Resonance Angiographycoil embolizationcompressed sensingintracranial aneurysmmagnetic resonance angiography

Identifiers

PMID35736881
PMCPMC9227072
OpenAlexW4283167209

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.