ArticleMembranes2022
Electromembrane Extraction of Posaconazole for Matrix-Assisted Laser Desorption/Ionization Mass Spectrometric Detection.
Article in Membranes, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 2 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 2 institutions in 1 country.
Funding
Abstract
A new mode of electromembrane extraction (EME) has been developed for detection via matrix-assisted laser desorption/ionization mass spectrometry (MALDI/MS). Posaconazole, extracted from 8 mL of a 10 mM trifluoroacetic acid solution onto a thin polyvinylidene difluoride (PVDF) membrane, was used as a model analyte. The transport was forced by an electrical potential difference between two electrodes inside the lumen of a hollow fiber and glass tube. Under an application of 80 V, cationic posaconazole in the sample solution moved toward the negative electrode inside the glass tube and was trapped by the PVDF membrane on the side. After 15 min of extraction, 3 μL of α-cyano-4-hydroxycinnamic acid (CHCA) solution was applied on top of the membrane, which was then analyzed by MALDI/MS. Under optimal extraction conditions, the calibration curve of posaconazole was linear over a concentration range of 0.10-100.00 nM. The limit of detection (LOD) at a signal-to-noise ratio of 3 was 0.03 nM with an enhancement factor of 138 for posaconazole. The application of this method to the determination of posaconazole in human serum samples was also successfully demonstrated.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.