Evidence map›Paper›PMID 35735956›Full record

ArticleJournal of imaging2022

Embedded Quantitative MRI T

Matti Hanhela, Antti Paajanen, Mikko J Nissi, Ville Kolehmainen

Abstract read
In one paragraph

Article in Journal of imaging, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Fast Compressed Sensing of 3D Radial TJournal of imaging · 2023
    Article
  2. SPICY: a method for single scan rotating frame relaxometry.Physical chemistry chemical physics : PCCP · 2023
    Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Matti HanhelaDepartment of Applied Physics, University of Eastern Finland, 70211 Kuopio, Finland.ORCID 0000-0001-5044-3203
Antti PaajanenDepartment of Applied Physics, University of Eastern Finland, 70211 Kuopio, Finland.ORCID 0000-0002-1763-2990
Mikko J NissiDepartment of Applied Physics, University of Eastern Finland, 70211 Kuopio, Finland.ORCID 0000-0002-5678-0689
Ville KolehmainenDepartment of Applied Physics, University of Eastern Finland, 70211 Kuopio, Finland.ORCID 0000-0002-5621-795X

Funding

Academy of Finland 325146Academy of Finland 336791Doctoral Programme in Science, Technology, and Computing (SCITECO) of the University of Eastern FinlandPäivikki and Sakari Sohlberg FoundationVilho, Yrjö and Kalle Väisälä Fund
6 · The paper itself

Abstract

Quantitative MRI (qMRI) methods allow reducing the subjectivity of clinical MRI by providing numerical values on which diagnostic assessment or predictions of tissue properties can be based. However, qMRI measurements typically take more time than anatomical imaging due to requiring multiple measurements with varying contrasts for, e.g., relaxation time mapping. To reduce the scanning time, undersampled data may be combined with compressed sensing (CS) reconstruction techniques. Typical CS reconstructions first reconstruct a complex-valued set of images corresponding to the varying contrasts, followed by a non-linear signal model fit to obtain the parameter maps. We propose a direct, embedded reconstruction method for T1ρ mapping. The proposed method capitalizes on a known signal model to directly reconstruct the desired parameter map using a non-linear optimization model. The proposed reconstruction method also allows directly regularizing the parameter map of interest and greatly reduces the number of unknowns in the reconstruction, which are key factors in the performance of the reconstruction method. We test the proposed model using simulated radially sampled data from a 2D phantom and 2D cartesian ex vivo measurements of a mouse kidney specimen. We compare the embedded reconstruction model to two CS reconstruction models and in the cartesian test case also the direct inverse fast Fourier transform. The T1ρ RMSE of the embedded reconstructions was reduced by 37-76% compared to the CS reconstructions when using undersampled simulated data with the reduction growing with larger acceleration factors. The proposed, embedded model outperformed the reference methods on the experimental test case as well, especially providing robustness with higher acceleration factors.

Indexed as

compressed sensingembedded reconstructionmodel-based reconstructionquantitative MRIT1rho mapping

Identifiers

PMID35735956
PMCPMC9225115

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.