Evidence map›Paper›PMID 35731540›Full record

ArticleTranslational vision science & technology2022

Corneal Lenticule Creation Using a New Solid-State Femtosecond Laser Measured by Spectral Domain OCT in a Porcine Eye Model.

Christoph Lwowski, Anna Voigt, Karel Van Keer, Thomas Kohnen

Abstract read
In one paragraph

Article in Translational vision science & technology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Keratorefractive Lenticule Extraction - KLEx.Klinische Monatsblatter fur Augenheilkunde · 2025
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Christoph LwowskiDepartment of Ophthalmology, Goethe-University Frankfurt am Main, Frankfurt am Main, Germany.
Anna VoigtDepartment of Ophthalmology, Goethe-University Frankfurt am Main, Frankfurt am Main, Germany.
Karel Van KeerDepartment of Ophthalmology, Goethe-University Frankfurt am Main, Frankfurt am Main, Germany.
Thomas KohnenDepartment of Ophthalmology, Goethe-University Frankfurt am Main, Frankfurt am Main, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: To determine the accuracy and precision of corneal lenticule creation with a new solid-state femtosecond laser in a porcine eye model. Methods: Corneal lenticule creation was performed using a new solid-state femtosecond laser on 60 porcine eyes with 10 subgroups. Optical coherence tomography images were acquired immediately after laser treatment. Cap thickness (CT), cap diameter (CD), and lenticule thickness (LT) were measured manually by three independent readers. Additionally, CT and LT were measured by an automated algorithm (aLT, aCT). Results: Measured LT was significantly greater than the intended LT (average difference 14.3 ± 5.6 µm, P < 0.001). aLT was closer but still significantly different from the intended LT (-2.9 ± 5.8 µm, P < 0.001). Measured CT showed no significant difference from the intended CT (2.6 ± 13.3, P = 0.145). aCT was significantly smaller compared to the intended CT (-9.6 ± 13.6, P < 0.001). Measured CD was significantly smaller compared to the intended CD (-0.21 ± 0.20 mm, P < 0.001). All lenticules were cut as planned with no laser-related complications. Conclusions: This new solid-state femtosecond laser used in our trial provides corneal lenticule creation in a porcine eye model comparable to other established systems. However, measuring those lenticules in the provided setting seems too challenging even when using semiautomated algorithms, which seems to be due to the experimental setting of the trial. Translational Relevance: This trial shows the precision and repeatability of corneal cuts performed by a new femtosecond laser that could translate to refractive corneal lenticule surgery.

Indexed as

Corneal Surgery, LaserAnimalsCorneaCorneal StromaLasers, ExcimerSwineTomography, Optical Coherence

Identifiers

PMID35731540
PMCPMC9233285

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390