Evidence map›Paper›PMID 35729631›Full record

ArticleBMC musculoskeletal disorders2022

Impact of keel saw blade design and thickness on the incidence of tibial plateau fracture and tibial implant-loosening in cementless medial UKR.

Lena Keppler, Steffen Klingbeil, Alexander Martin Keppler, Johannes Becker, Christian Fulghum, Björn Michel, Kilian Voigts, Wolfgang Reng

Open access · goldAbstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.1field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 1 country.

Lena KepplerBG Trauma Center Murnau, Trauma Surgery, Prof. Kuentscher Straße 8, 82418, Murnau, Germany.
Steffen KlingbeilKlinikum Garmisch-Partenkirchen, Endogap, Joint Replacement Institute, Auenstraße 6, 82467, Garmisch-Partenkirchen, Germany.
Alexander Martin KepplerDepartment of Orthopaedics and Trauma Surgery, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, 81377, Munich, Germany.
Johannes BeckerKlinikum Garmisch-Partenkirchen, Endogap, Joint Replacement Institute, Auenstraße 6, 82467, Garmisch-Partenkirchen, Germany.
Christian FulghumKlinikum Garmisch-Partenkirchen, Endogap, Joint Replacement Institute, Auenstraße 6, 82467, Garmisch-Partenkirchen, Germany.
Björn MichelKlinikum Garmisch-Partenkirchen, Endogap, Joint Replacement Institute, Auenstraße 6, 82467, Garmisch-Partenkirchen, Germany.
Kilian VoigtsKlinikum Garmisch-Partenkirchen, Endogap, Joint Replacement Institute, Auenstraße 6, 82467, Garmisch-Partenkirchen, Germany.
Wolfgang RengKlinikum Garmisch-Partenkirchen, Endogap, Joint Replacement Institute, Auenstraße 6, 82467, Garmisch-Partenkirchen, Germany. wolfgang.reng@klinikum-gap.de.
Garmisch-Partenkirchen Medical Center · DEBerufsgenossenschaftliche Unfallklinik Murnau · DELudwig-Maximilians-Universität München · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundTibial plateau fractures and tibial implant- loosening are severe complications in cementless unicompartmental knee replacement (UKR). The tibial keel preparation is particularly demanding and different saw blades can be used. It was hypothesized that different blade designs and thickness have an influence on the frequency of tibial plateau fractures and implant-loosening in cementless medial UKR.

methods1258 patients with cementless medial UKR were included in this retrospective study between 2013 and 2020. The tibial keel cut was performed either with a double keel saw blade (DKS; 2.8 mm) and added hand guided pick or a mono reciprocating saw blade (RKB) of different thickness (2.5 mm; 2.65 mm; 2.75 mm). Tibial plateau fracture and loosening were demonstrated by standard two-plane radiographs. Tibial implant-loosening was defined as complete radiolucency and implant migration. Fracture and loosening were combined with pain and loss of function.

resultsIn 126 patients (10%) the tibial keel was prepared with DKS, in 407 patients (32.4%) with RKB 2.5 mm, in 330 patients (26.2%) with RKB 2.65 mm and in 395 patients (31.4%) with 2.75 mm. In 4 patients (3.17%) with DKS tibial plateau fracture occurred, in 4 patients (0.99%) with 2.5 mm RKB, in 3 patients (0.92%) with 2.65 mm RKB and in 1 patient (0.25%) with 2.75 mm RKB. Significantly fewer fractures occurred with a RKB design (p = 0.007). A negative correlation between fracture incidence and RKB saw blade thickness was found (Spearman-r = - 0.93). No difference for tibial implant-loosening was shown (p = 0.51).

conclusionDifferent blade designs and thickness have a significant influence on the incidence of tibial plateau fractures and aseptic tibial implant-loosening. The incidence of tibial plateau fractures in cementless medial UKR can be reduced by changing the design and thickness of the tibial keel saw blade. Greater thickness of RKB leads to significantly fewer tibial plateau fractures while the incidence of implant-loosening is not increasing.

trial registrationThis study was retrospectively registered and ethical approval was waived by the local ethical committee (No. 2020-1174).

Indexed as

Arthroplasty, Replacement, KneeKnee ProsthesisTibial FracturesHumansIncidenceProsthesis DesignRetrospective StudiesFracture incidenceInfluenceOutcomeRevision surgerySaw blade

Identifiers

PMID35729631
PMCPMC9210701
OpenAlexW4283210392

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.