Evidence map›Paper›PMID 35726779›Full record

ArticleJournal of magnetic resonance imaging : JMRI2023

Comparison of 2D and 4D Flow MRI in Neonates Without General Anesthesia.

Pia Sjöberg, Erik Hedström, Katrin Fricke, Petter Frieberg, Constance G Weismann, Petru Liuba, Marcus Carlsson, Johannes Töger

Open access · hybridAbstract read
In one paragraph

Article in Journal of magnetic resonance imaging : JMRI, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
2.3field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 17 citations in OpenAlex.

  1. Comparison of free-running whole-heart five-dimensional and four-dimensional flow imaging to standard two-dimensional flow in patients with congenital heart disease.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2026
    Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. 4D Flow cardiovascular magnetic resonance consensus statement: 2023 update.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2023
    Review
  9. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Pia SjöbergClinical Physiology, Department of Clinical Sciences Lund, Lund University, Skåne University Hospital, Lund.ORCID 0000-0002-9721-2880
Erik HedströmClinical Physiology, Department of Clinical Sciences Lund, Lund University, Skåne University Hospital, Lund.
Katrin FrickePediatric Heart Center, Department of Clinical Sciences Lund, Lund University, Skåne University Hospital, Lund, Sweden.
Petter FriebergClinical Physiology, Department of Clinical Sciences Lund, Lund University, Skåne University Hospital, Lund.
Constance G WeismannPediatric Heart Center, Department of Clinical Sciences Lund, Lund University, Skåne University Hospital, Lund, Sweden.
Petru LiubaPediatric Heart Center, Department of Clinical Sciences Lund, Lund University, Skåne University Hospital, Lund, Sweden.
Marcus CarlssonClinical Physiology, Department of Clinical Sciences Lund, Lund University, Skåne University Hospital, Lund.
Johannes TögerClinical Physiology, Department of Clinical Sciences Lund, Lund University, Skåne University Hospital, Lund.
Lund University · SE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundNeonates with critical congenital heart disease require early intervention. Four-dimensional (4D) flow may facilitate surgical planning and improve outcome, but accuracy and precision in neonates are unknown. PURPOSE: To 1) validate two-dimensional (2D) and 4D flow MRI in a phantom and investigate the effect of spatial and temporal resolution; 2) investigate accuracy and precision of 4D flow and internal consistency of 2D and 4D flow in neonates; and 3) compare scan time of 4D flow to multiple 2D flows. STUDY TYPE: Phantom and prospective patients. POPULATION: A total of 17 neonates with surgically corrected aortic coarctation (age 18 days [IQR 11-20]) and a three-dimensional printed neonatal aorta phantom. FIELD STRENGTH/SEQUENCE: 1.5T, 2D flow and 4D flow. ASSESSMENT: In the phantom, 2D and 4D flow volumes (ascending and descending aorta, and aortic arch vessels) with different resolutions were compared to high-resolution reference 2D flow. In neonates, 4D flow was compared to 2D flow volumes at each vessel. Internal consistency was computed as the flow volume in the ascending aorta minus the sum of flow volumes in the aortic arch vessels and descending aorta, divided by ascending aortic flow. STATISTICAL TESTS: Bland-Altman plots, Pearson correlation coefficient (r), and Student's t-tests.

resultsIn the phantom, 2D flow differed by 0.01 ± 0.02 liter/min with 1.5 mm spatial resolution and -0.01 ± 0.02 liter/min with 0.8 mm resolution; 4D flow differed by -0.05 ± 0.02 liter/min with 2.4 mm spatial and 42 msec temporal resolution, -0.01 ± 0.02 liter/min with 1.5 mm, 42 msec resolution and -0.01 ± 0.02 liter/min with 1.5 mm, 21 msec resolution. In patients, 4D flow and 2D flow differed by -0.06 ± 0.08 liter/min. Internal consistency in patients was -11% ± 17% for 2D flow and 5% ± 13% for 4D flow. Scan time was 17.1 minutes [IQR 15.5-18.5] for 2D flow and 6.2 minutes [IQR 5.3-6.9] for 4D flow, P < 0.0001. DATA

conclusionNeonatal 4D flow MRI is time efficient and can be acquired with good internal consistency without contrast agents or general anesthesia, thus potentially expanding 4D flow use to the youngest and smallest patients. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 2.

Indexed as

Imaging, Three-DimensionalMagnetic Resonance ImagingAdolescentAnesthesia, GeneralBlood Flow VelocityHumansInfant, NewbornProspective StudiesReproducibility of Resultsaortic coarctationcongenital heart diseasefour-dimensional flow

Identifiers

PMID35726779
PMCPMC10084310
OpenAlexW4283220457

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked