Evidence map›Paper›PMID 35720681›Full record

ArticleJournal of innovative optical health sciences2022

Broadband diffuse optical spectroscopy of two-layered scattering media containing oxyhemoglobin, deoxyhemoglobin, water, and lipids.

Giles Blaney, Martina Bottoni, Angelo Sassaroli, Cristianne Fernandez, Sergio Fantini

Open access · goldAbstract read
In one paragraph

Article in Journal of innovative optical health sciences, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.9field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 2 countries.

Giles BlaneyDepartment of Biomedical Engineering, Tufts University 4 Colby St, Medford, MA 02155, USA.
Martina BottoniDepartment of Biomedical Engineering, Tufts University 4 Colby St, Medford, MA 02155, USA.
Angelo SassaroliDepartment of Biomedical Engineering, Tufts University 4 Colby St, Medford, MA 02155, USA.
Cristianne FernandezDepartment of Biomedical Engineering, Tufts University 4 Colby St, Medford, MA 02155, USA.
Sergio FantiniDepartment of Biomedical Engineering, Tufts University 4 Colby St, Medford, MA 02155, USA.
Tufts University · USPolytechnic University of Turin · IT

Funding

Coherent hemodynamics spectroscopy for cerebral autoregulation and blood flowR01NS095334 · NINDS · TUFTS UNIVERSITY MEDFORD · PI FANTINI, SERGIO · 2016 to 2020
$2.6M
Dual-slope method for enhanced depth sensitivity in frequency-domain near-infrared spectroscopyR01EB029414 · NIBIB · TUFTS UNIVERSITY MEDFORD · PI SERGIO FANTINI · 2021 to 2026
$2.5M
NIBIB NIH HHS R01 EB029414NINDS NIH HHS R01 NS095334
6 · The paper itself

Abstract

We investigated the relationship between chromophore concentrations in two-layered scattering media and the apparent chromophore concentrations measured with broadband optical spectroscopy in conjunction with commonly used homogeneous medium inverse models. We used diffusion theory togenerate optical data from a two-layered distribution of relevant tissue absorbers, namely, oxyhemoglobin, deoxyhemoglobin, water, and lipids, with a top-layer thickness in the range 1-15 mm. The generated data consisted of broadband continuous-wave (CW) diffuse reflectance in the wavelength range 650-1024 nm, and frequency-domain (FD) diffuse reflectance at 690 and 830 nm; two source-detector distances of 25 and 35 mm were used to simulate a dual-slope technique. The data were inverted using diffusion theory for a semi-infinite homogeneous medium to generate reduced scattering coefficients at 690 and 830 nm (from FD data) and effective absorption spectra in the range 650-1024 nm (from CW data). The absorption spectra were then converted into effective total concentration and oxygen saturation of hemoglobin, as well as water and lipid concentrations. For absolute values, it was found that the effective hemoglobin parameters are typically representative of the bottom layer, whereas water and lipid represent some average of the respective concentrations in the two layers. For concentration changes, lipid showed a significant cross-talk with other absorber concentrations, thus indicating that lipid dynamics obtained in these conditions may not be reliable. These systematic simulations of broadband spectroscopy of two-layered media provide guidance on how to interpret effective optical properties measured with similar instrumental setups under the assumption of medium homogeneity.

Indexed as

Broadband spectroscopyheterogeneous forward modelhomogeneous inverse modelpartial-volume effecttwo-layer medium

Identifiers

PMID35720681
PMCPMC9203000
OpenAlexW4226209290

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.