Dual-Slope Diffuse Reflectance Instrument for Calibration-Free Broadband Spectroscopy.

Giles Blaney, Ryan Donaldson, Samee Mushtak, Han Nguyen, Lydia Vignale, Cristianne Fernandez, Thao Pham, Angelo Sassaroli, Sergio Fantini

Open access · goldAbstract read
In one paragraph

Article in Applied sciences (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
3.5field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 29 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 1 institution in 1 country.

Giles BlaneyDepartment of Biomedical Engineering, Tufts University, Medford, MA 02155, USA.ORCID 0000-0003-3419-4547
Ryan DonaldsonDepartment of Biomedical Engineering, Tufts University, Medford, MA 02155, USA.
Samee MushtakDepartment of Biomedical Engineering, Tufts University, Medford, MA 02155, USA.ORCID 0000-0003-1201-3274
Han NguyenDepartment of Biomedical Engineering, Tufts University, Medford, MA 02155, USA.
Lydia VignaleDepartment of Biomedical Engineering, Tufts University, Medford, MA 02155, USA.ORCID 0000-0002-6276-348X
Cristianne FernandezDepartment of Biomedical Engineering, Tufts University, Medford, MA 02155, USA.ORCID 0000-0002-6446-8310
Thao PhamDepartment of Biomedical Engineering, Tufts University, Medford, MA 02155, USA.ORCID 0000-0002-7667-6897
Angelo SassaroliDepartment of Biomedical Engineering, Tufts University, Medford, MA 02155, USA.ORCID 0000-0003-4233-7165
Sergio FantiniDepartment of Biomedical Engineering, Tufts University, Medford, MA 02155, USA.ORCID 0000-0001-5116-525X
Tufts University · US

Funding

Coherent hemodynamics spectroscopy for cerebral autoregulation and blood flowR01NS095334 · NINDS · TUFTS UNIVERSITY MEDFORD · PI FANTINI, SERGIO · 2016 to 2020
$2.6M
NINDS NIH HHS R01 NS095334
6 · The paper itself

Abstract

This work presents the design and validation of an instrument for dual-slope broadband diffuse reflectance spectroscopy. This instrument affords calibration-free, continuous-wave measurements of broadband absorbance of optically diffusive media, which may be translated into absolute absorption spectra by adding frequency-domain measurements of scattering at two wavelengths. An experiment on a strongly scattering liquid phantom (milk, water, dyes) confirms the instrument's ability to correctly identify spectral features and measure absolute absorption. This is done by sequentially adding three dyes, each featuring a distinct spectral absorption, to the milk/water phantom. After each dye addition, the absorption spectrum is measured, and it is found to reproduce the spectral features of the added dye. Additionally, the absorption spectrum is compared to the absorption values measured with a commercial frequency-domain instrument at two wavelengths. The measured absorption of the milk/water phantom quantitatively agrees with the known water absorption spectrum (

Indexed as

absorption spectrabroadband diffuse reflectance spectroscopydual-slopefrequency-domain near-infrared spectroscopy

Identifiers

PMID35719895
PMCPMC9204805
OpenAlexW3129604590

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.