Evidence map›Paper›PMID 35715775›Full record

ArticleBMC musculoskeletal disorders2022

Biomechanical comparison of different interspinous process devices in the treatment of lumbar spinal stenosis: a finite element analysis.

Zhengpeng Liu, Shuyi Zhang, Jia Li, Hai Tang

Open access · goldAbstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
1.9field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 16 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Review
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Zhengpeng LiuDepartment of Orthopaedics, Beijing Friendship Hospital, Capital Medical University, Xicheng District, Beijing, 101100, China.
Shuyi ZhangDepartment of Spine Surgery, Affiliated Hospital of Chengde Medical University, Chengde, 067000, Hebei, China.
Jia LiDepartment of Joint Surgery, Affiliated Hospital of Chengde Medical University, Chengde, 067000, Hebei, China.
Hai TangDepartment of Orthopaedics, Beijing Friendship Hospital, Capital Medical University, Xicheng District, Beijing, 101100, China. tanghai20219@163.com.
Chengde Medical University · CNCapital Medical University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundLumbar spinal stenosis (LSS) is a common disease among elderly individuals, and surgery is an effective treatment. The development of minimally invasive surgical techniques, such as the lumbar interspinous process device (IPD), has provided patients with more surgical options.

objectiveTo investigate the biomechanical properties of different IPDs, including BacFuse, X-Stop and Coflex, in the treatment of LSS.

methodsBased on the computed tomography images of a patient with LSS, four finite element (FE) models of L3-S5 were created in this study. The FE models included a surgical model of the intact lumbar spine and surgical models of the lumbar IPDs BacFuse, X-Stop, and Coflex. After validating the models, they were simulated for four physiological motions: flexion, extension, lateral bending and axial rotation, and range of motion (ROM). Stress distribution of discs and facet joints in each segment, stress distribution of the spinous process in the operated section, and stress distribution of the internal fixation were compared and analysed.

resultsCompared to the model of the intact lumbar spine, the other three models showed a decrease in ROM and disc and facet joint stresses in the surgical segment during movement and an increase in ROM and disc and facet joint stresses in the adjacent segments. These effects were greater for the proximal adjacent segment with BacFuse and more pronounced for the distal adjacent segment with Coflex, while X-Stop had the greatest stress effect on the spinous process in the surgical segment.

conclusionBacFuse, Coflex and X-Stop could all be implemented to effectively reduce extension and disc and facet joint stresses, but they also increase the ROM and disc and facet joint stresses in adjacent segments, which may cause degeneration.

Indexed as

Spinal FusionSpinal StenosisAgedBiomechanical PhenomenaFinite Element AnalysisHumansLumbar VertebraeRange of Motion, ArticularBacFuseBiomechanicsCoflexFinite element analysisInterspinous process devicesLumbar spinal stenosisX-Stop

Identifiers

PMID35715775
PMCPMC9204899
OpenAlexW4283025342

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.