Evidence map›Paper›PMID 35713940›Full record

ArticleJMIR cardio2022

Virtual Reality Cardiac Surgical Planning Software (CorFix) for Designing Patient-Specific Vascular Grafts: Development and Pilot Usability Study.

Byeol Kim, Phong Nguyen, Yue-Hin Loke, Vincent Cleveland, Xiaolong Liu, Paige Mass, Narutoshi Hibino, Laura Olivieri, Axel Krieger

Open access · goldAbstract read
In one paragraph

Article in JMIR cardio, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 1 pooled it
1.7field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 1 synthesis or guideline pooled it, 11 citations in OpenAlex.

  1. Pooled it
  2. Review
  3. Article
  4. Benefit of virtual reality during visceral artery aneurysms open and endovascular surgery planning.Journal of vascular surgery cases and innovative techniques · 2025
    Article
  5. Surgical planning in virtual reality: a systematic review.Journal of medical imaging (Bellingham, Wash.) · 2024
    Review
  6. Review
  7. Review
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 4 institutions in 1 country.

Byeol KimDepartment of Mechanical Engineering, Johns Hopkins University, Baltimore, MD, United States.ORCID https://orcid.org/0000-0001-8289-9424
Phong NguyenDepartment of Computer Science, University of Maryland, College Park, MD, United States.ORCID https://orcid.org/0000-0002-0737-2064
Yue-Hin LokeDivision of Cardiology, Children's National Hospital, Washington, DC, United States.ORCID https://orcid.org/0000-0003-1003-1903
Vincent ClevelandDivision of Cardiology, Children's National Hospital, Washington, DC, United States.ORCID https://orcid.org/0000-0001-8235-9962
Xiaolong LiuDepartment of Mechanical Engineering, Johns Hopkins University, Baltimore, MD, United States.ORCID https://orcid.org/0000-0001-5335-3473
Paige MassDivision of Cardiology, Children's National Hospital, Washington, DC, United States.ORCID https://orcid.org/0000-0002-5778-9300
Narutoshi HibinoDepartment of Surgery, University of Chicago, Chicago, IL, United States.ORCID https://orcid.org/0000-0003-4551-9079
Laura OlivieriDivision of Cardiology, Children's National Hospital, Washington, DC, United States.ORCID https://orcid.org/0000-0002-3783-0783
Axel KriegerDepartment of Mechanical Engineering, Johns Hopkins University, Baltimore, MD, United States.ORCID https://orcid.org/0000-0001-8169-075X
Children's National · USJohns Hopkins University · USUniversity of Chicago · USUniversity of Maryland, College Park · US

Funding

Patient specific 3D printed tissue engineered vascular graft for aortic reconstruction designed by artificial intelligence algorithm.R01HL143468 · NHLBI · UNIVERSITY OF CHICAGO · PI FUGE, MARK, HIBINO, NARUTOSHI · 2018 to 2021
$2.7M
Patient Specific Tissue Engineered Vascular Graft Creation Using 3D Printing TechnologyR33HD090671 · NICHD · UNIVERSITY OF CHICAGO · PI HIBINO, NARUTOSHI, KRIEGER, AXEL · 2019 to 2021
$1.2M
Patient Specific Tissue Engineered Vascular Graft Creation Using 3D Printing TechnologyR21HD090671 · NICHD · JOHNS HOPKINS UNIVERSITY · PI HIBINO, NARUTOSHI, KRIEGER, AXEL · 2017 to 2018
$484k
NHLBI NIH HHS R01 HL143468NICHD NIH HHS R21 HD090671
6 · The paper itself

Abstract

backgroundPatients with single ventricle heart defects receive 3 stages of operations culminating in the Fontan procedure. During the Fontan procedure, a vascular graft is sutured between the inferior vena cava and pulmonary artery to divert deoxygenated blood flow to the lungs via passive flow. Customizing the graft configuration can maximize the long-term benefits. However, planning patient-specific procedures has several challenges, including the ability for physicians to customize grafts and evaluate their hemodynamic performance.

objectiveThe aim of this study was to develop a virtual reality (VR) Fontan graft modeling and evaluation software for physicians. A user study was performed to achieve 2 additional goals: (1) to evaluate the software when used by medical doctors and engineers, and (2) to explore the impact of viewing hemodynamic simulation results in numerical and graphical formats.

methodsA total of 5 medical professionals including 4 physicians (1 fourth-year resident, 1 third-year cardiac fellow, 1 pediatric intensivist, and 1 pediatric cardiac surgeon) and 1 biomedical engineer voluntarily participated in the study. The study was pre-scripted to minimize the variability of the interactions between the experimenter and the participants. All participants were trained to use the VR gear and our software, CorFix. Each participant designed 1 bifurcated and 1 tube-shaped Fontan graft for a single patient. A hemodynamic performance evaluation was then completed, allowing the participants to further modify their tube-shaped design. The design time and hemodynamic performance for each graft design were recorded. At the end of the study, all participants were provided surveys to evaluate the usability and learnability of the software and rate the intensity of VR sickness.

resultsThe average times for creating 1 bifurcated and 1 tube-shaped graft after a single 10-minute training session were 13.40 and 5.49 minutes, respectively, with 3 out 5 bifurcated and 1 out of 5 tube-shaped graft designs being in the benchmark range of hepatic flow distribution. Reviewing hemodynamic performance results and modifying the tube-shaped design took an average time of 2.92 minutes. Participants who modified their tube-shaped graft designs were able to improve the nonphysiologic wall shear stress (WSS) percentage by 7.02%. All tube-shaped graft designs improved the WSS percentage compared to the native surgical case of the patient. None of the designs met the benchmark indexed power loss.

conclusionsVR graft design software can quickly be taught to physicians with no engineering background or VR experience. Improving the CorFix system could improve performance of the users in customizing and optimizing grafts for patients. With graphical visualization, physicians were able to improve WSS percentage of a tube-shaped graft, lowering the chance of thrombosis. Bifurcated graft designs showed potential strength in better flow split to the lungs, reducing the risk for pulmonary arteriovenous malformations.

Indexed as

congenital heart diseaseheartsurgerysurgical planningusability studyvirtual reality

Identifiers

PMID35713940
PMCPMC9250062
OpenAlexW4283075056

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.